STYLOS-S24: 

ACCESSORIES

For more kit accessories please contact 

Sales

 on 

0115 9210 430

Code(s)

Description

RADIO KEYPAD SELECTORS

806SL-0170

SELT1W4G - Surface-mounted, 433.92 MHz radio-frequency keypad selector, 12-keys, with blue backlighting. 25 savable 

codes and password to access the programming mode. Settable in Rolling Code or Fixed Code mode. RAL7024 Grey colour.

806SL-0180

SELT1W8G - Surface-mounted, 868.35 MHz radio-frequency keypad selector, 12-keys, with blue backlighting. 25 savable 

codes and password to access the programming mode. Settable in Rolling Code or Fixed Code mode. RAL7024 Grey colour.

001

AF868

Plug-in 868.35 MHz radio frequency control card.

Required for 806SL-0180.

BLUETOOTH SELECTORS

806SL-0210

SELB1SDG1 - Surface-mounted with blue backlighting, for 15 users. RAL7024 Grey colour.

806SL-0240

SELB1SDG2 - Surface-mounted with blue backlighting, for 50 users. RAL7024 Grey colour.

806SL-0250

SELB1SDG3 - Surface-mounted with blue backlighting, for 250 users. RAL7024 Grey colour.

TRANSPONDER SELECTORS

806SL-0300

SELR1BDG - Surface-mounted Bus transponder reader for cards, keyfobs and TAG (Manchester protocol) with blue 

backlighting. RAL7024 Grey colour.

806SL-0310

SELR2BDG - Flush-mounted Bus transponder reader for cards, keyfobs and TAG (Manchester protocol) with blue 

backlighting. RAL7024 Grey colour.

001

R700

Programming board and access control management when used with transponder.

Required for 806SL-0300 and 806SL-0310.

HARDWIRED KEYPAD SELECTORS

 

806SL-0280

SELT1BDG - Surface-mounted 12 button Bus keypad with blue backlighting. 

RAL7024 Grey colour. 

 

806SL-0290

SELT2BDG - Flush-mounted 12 button Bus keypad with blue backlighting. 

RAL7024 Grey colour.  

 

001

R800

Control board for programming and access-control management via keypad selectors. 

Required for 806SL-0280 and 806SL-0290.

TOP - ROLLING CODE

8K06TS-001

TOPD4RXM - 6 packaged dual frequency 4 button rolling code transmitters. 

4,294,967,896 combinations.

PHOTOCELLS

  

Surface mounted. Synchronised beam, multiple pairs of photocells can be applied to the same system,  

even at double height and/or close to each other - with no interference issues (cross talk).

001

DIR10

Pair of 12 - 24 V AC - DC outdoor photocells - range 10m.

001

DIR20

Pair of 12 - 24 V AC - DC outdoor photocells - range 20m.

001

DIR30

Pair of 12 - 24 V AC - DC outdoor photocells - range 30m.

PHOTOCELL column

001

DIRL

Natural finish aluminium post. H = 500mm

001

DIRLN

Black anodised aluminium post. H = 500mm

001

DIRCG

Silver RAL9006, PVC post. H = 500mm

ZL92Z: 

SAFETY

FUNCTIONS > CX Input, CY Input

SAFETY INPUTS

If during the reverse motion a diff erent safety is triggered the automation will perform the appropriate action for the new triggered 

safety, should multiple safeties be triggered at the same time the automation will be halted at its current position.

SENSITIVE EDGES

C7  

REOPENING DURING CLOSING

•  When the automation is in its closing cycle and the safety circuit is triggered the automation will reverse its motion until it reaches its fully open 

position again.

•  If the auto closing option is enabled and the safety is no longer triggered the auto closing countdown will commence, once completed the 

automation will start the closing cycle again.

•  If the auto closing option is not enabled the automation will return to the fully open position awaiting another activation from a command device.

C8  

RECLOSING DURING OPENING

•  When the automation is in its opening cycle and the safety circuit is triggered the automation will reverse its motion until it reaches its fully 

closed position again.

•  Once the automation has reached the fully closed position it will require another activation from a command device to restart.

The above sequence will be attempted 3 times before the automation is halted, the automation will then 

require activation from a command device to restart.

C1   

REOPENING DURING CLOSING

•  When the automation is in its closing cycle and the safety circuit is triggered the automation will stop and reverse its motion until it reaches its 

fully open position again.

•  If the auto closing option is enabled and the safety is no longer triggered the auto closing countdown will commence, once completed the 

automation will start the closing cycle again.

•  If the auto closing option is not enabled the automation will return to the fully open position awaiting another activation from a command device.

C2  

RECLOSING DURING OPENING

•  When the automation is in its opening cycle and the safety circuit is triggered the automation will stop and reverse its motion until it reaches its 

fully closed position again.

•  Once the automation has reached the fully closed position it will require another activation from a command device to restart.

C3  

PARTIAL STOP

•  When the automation is in its opening cycle and the safety circuit is triggered the automation will stop.

•  If the auto closing option is enabled and the safety is no longer triggered the auto closing countdown will commence, once completed the 

automation will start closing the device.

C4  

OBSTRUCTION WAIT

•  When the automation is in either its opening or closing cycle and the safety circuit is triggered the automation will stop.

•  Once the safety is no longer triggered the automation will carry on the cycle it was performing at the time it was interrupted.

Summary of Contents for 8K01MB-0576 STYLO KIT

Page 1: ...for a single swing gate weighing up to 100kg per leaf max width 1 8m QUICK SETUP GUIDE Typical gate setup geometry Gate motor manual release Kit wiring diagram Control panel guide safety TO BE READ I...

Page 2: ...ode Transmitter STYLO ME Motor x2 8K01MB 0576 KIT CONTENTS AF43S Radio Frequency Card 1 Kit Contents 2 Safety Instructions 3 Typical Gate Setup 4 Geometry 5 Manual Release Instructions 6 Kit Wiring Di...

Page 3: ...ssing through the gate Keep feet away from the bottom of the gate during operation Do not operate the gate by remote control unless it is in view Do not attempt to block or interfere with the gate mov...

Page 4: ...cells are used in pairs one transmitter and one receiver They should be installed between 500 600mm from the ground facing each other Power for the photocells is taken from the control panel 24v AC Th...

Page 5: ...the slower the opening speed and the greater the gear motor s thrust Opening A mm C mm D mm 90 90 0 200 400 90 230 180 300 135 230 0 300 D A C OUTward OPENING gates For outward opening gate geometry...

Page 6: ...the gate and return the release lever back to its original position pushed completely back into place Take the key out and replace the cap B Attempt to manually move the gate to ensure it is fully en...

Page 7: ...7 ZL92Z Control Panel 10 2 TX C NC TX 2 RX TX DIR Photocells Cable length RX 4 Core 0 5mm Flex TX 4 Core 0 5mm Flex 1m 30m Mains Supply 230 V AC Cable length 1m 20m 3 Core 1 5mm 20m 30m 3 Core 2 5mm...

Page 8: ...motor cables for motor 2 Connections M2 N2 Leave the gate in the halfway position 9 Setup the Encoder A 3 1 10 The Gate will now perform a close and open cycle 12 Exit the programming using the button...

Page 9: ...l now appear on the screen Press and release a button on a transmitter the number on the screen will increment by one for each button pressed A maximum of 25 individual buttons can be saved Remove tra...

Page 10: ...activation from a command device to restart C1 REOPENING DURING CLOSING When the automation is in its closing cycle and the safety circuit is triggered the automation will stop and reverse its motion...

Page 11: ...blue backlighting RAL7024 Grey colour 806SL 0310 SELR2BDG Flush mounted Bus transponder reader for cards keyfobs and TAG Manchester protocol with blue backlighting RAL7024 Grey colour 001R700 Programm...

Page 12: ...House Maxted Road Maylands Ind Est Hemel Hempstead Herts HP2 7DX Tel 01442 230 800 CAME BPT Ireland Unit 9 The Westway Centre Ballymount Dublin 12 Tel 353 0 1 450 7442 8K01MB 0576 QS0922 2022 EN YOU...

Reviews: