background image

CAME S.p.A.

Came cancelli automatici S.p.A.
is certified for Quality and Environment

UNI EN ISO 9001
UNI EN ISO 14001
BS OHSAS 18001

CAME - North

Unit 1B

Sills Road

Willow Farm Business Park

Castle Donington

DE74 2US

Tel:

 0115 921 0430

CAME - South

Liberta House  

Maxted Road

Maylands Ind. Est.

Hemel Hempstead

Herts

HP2 7DX 

Tel:

 01442 230 800

CAME BPT - Ireland

Unit 9

The Westway Centre

Ballymount

Dublin 12

Tel:

 +353 (0)1 450 7442

© 8K01MI-0523-QS0922 - 2022 - EN
YOU MAY NOT EVEN PARTIALLY REPRODUCE THIS DOCUMENT 
CAME RESERVES THE RIGHT TO MAKE ANY CHANGES TO THIS DOCUMENT AT ANY TIME 
THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT OBLIGATION TO GIVE PRIOR NOTICE BY CAME S.P.A, E&OE

Summary of Contents for 8K01MI-0523

Page 1: ...a single swing gate weighing up to 400kg max width 3 5m TO BE READ IN CONJUNCTION WITH THE FULL INSTRUCTION MANUAL ZLX24 PANEL VERSION QUICK SETUP GUIDE Typical gate setup geometry Gate motor manual release Kit wiring diagram Control panel guide safety ...

Page 2: ...SM 10 Commissioning via App 11 Commissioning via Panel 12 Safety Options 13 Replacing the SIM Card 14 Optional Accessories ZLX24SA Control Panel AF43S Radio Frequency Card FROG CFN Foundation Box FROGA24E Motor x2 DIR10 Pair of Photocells top a433n Tuned Antenna TOP44RBN Rolling code Transmitter RGSM001S Gateway Module RSE Connection Card SIM May be preinstalled in RGSM001S A4366 Release Device wi...

Page 3: ...passing through the gate Keep feet away from the bottom of the gate during operation Do not operate the gate by remote control unless it is in view Do not attempt to block or interfere with the gate movement during operation Under no circumstances should you attempt to modify the gate automation system Ensure that your gate is serviced at 3 to 12 month intervals dependent on number of openings by ...

Page 4: ...hazard Use cable glands to connect the devices to the control panel One of these must be used exclusively for the power supply cable All holes should be sealed to avoid ingression and maintain the IP54 protection rating Only a competent service provider should open the enclosure and adjust the settings The photocells are used in pairs one transmitter and one receiver They should be installed betwe...

Page 5: ...motor Manually open the leaf Position the gearmotor over the threaded pins of the casing and fasten it p 7 Manual FA01302 EN 02 2019 CAME S p A The contents of this manual may change at any time and without notice Original instructions INSTALLATION installed The drawings refer to the right side gearmotor Preliminary operations The preliminary operations for installation concern the foundation box ...

Page 6: ... once power is restored to fully engage the system Please take care when operating the system in this manner The FROG underground system is supplied with one of three release mechanisms a triangular key system 01 a DIN key system 02 or a lever system 03 Basic Maintenance Hints Tips Lift manual release tabs spray the locks on both sides with suitable penetrating lubricant Spray into the lock at the...

Page 7: ... 20m 30m 3 Core 2 5mm n encoder cable length E Cable Belden 8723 or equivalent Max 30m RSE Set RSE jumper to OFF AF43S Plug in TOP A433N Antenna Cable length RG58 Max 5m DIR Photocells Cable length RX 4 Core 0 5mm Flex TX 4 Core 0 5mm Flex 1m 30m 10 2 TX C NC TX 2 RX TX ZLX24SA Control Panel RGSM001S Gateway Module Cable length Max 3m power 10 2 A B GND ...

Page 8: ...gth or availability and therefore will not be held liable for lack of service came automation internet came cloud setup app for the installer GET IT ON AppStore GET IT ON automation app for the end user GET IT ON AppStore GET IT ON System Frequency Approx Movements Est SIM Life Based on Usage Occasional Usage Approx 5 gate manoeuvres per week 4 7 Years Average Usage Approx 3 4 gate manoeuvres per ...

Page 9: ... indicating the RGSM001S is registered on a GSM network 2 POWER LED Green The LED will flash 5x sec indicating the RGSM001S is not yet configured on the Connect platform antenna bracket Fitting instructions Make sure your kit contains the antenna bracket and cable Remove the safety screw from the cable Tighten the safety screw until the cable is secure Screw the bracket into place using the two ho...

Page 10: ...ive an email containing your log in information and request to confirm the account Should the email not arrive please check your junk folder download the connect setup app adding the rgsm gateway to your technician account technician connect setup app 1 3 2 If you have an existing account please move to step 3 Important The installation must be carried out by skilled and qualified personnel Mr Wil...

Page 11: ...40825 Mr Wilson Maple Avenue Derby Front Gate 123456789ABCDEF WILSON DERBY 8988228066602040825 Mr Wilson Maple Avenue Derby Front Gate CAME RGSM Keycode 123456789ABCDEF 1NCE SIM No 8988228066602040825 CAME RGSM Keycode 123456789ABCDEF 1NCE SIM No 8988228066602040825 Keycode Must be completed using the exact CAME RGSM KEYCODE details which can be found on the GSM Support Card and on the GSM module ...

Page 12: ...o this using the Installer Setup App The information can be found in the Gateway Information Device configured Online 123456789ABCDEF WILSON DERBY 8988228066602040825 Mr Wilson Maple Avenue Derby Front Gate 0374019A RGSM Standalone Gateway 0 1 for END USERS By naming the gateway to our recommendation should your customer need to access the SIM number for future top up purposes they will be able to...

Page 13: ...e on solid and the BLUE 1 flashing 1x sec CONGRATULATIONS the RGSM001S has now been successfully added to the Connect platform adding the rgsm gateway to your technician account continued 3 OUT1 OUT2 Keycode 123456789ABCDE F MATR 54051 6 300mAE GSM 900 33dBm DCS 1800 30dBm 869 5MHz 14dBm 24V CONNECT 123 4 GND A N T 10 2 COM IN2 COM IN1 B A 1A 30V RGSM001S 1 2 3 ...

Page 14: ...p down list Enter a name and description then press Add adding automation 1 FROG 24V ZLX24S Automation for swing gates FROG E M2 Front Gates Front Gates 1 Installer Tip The Name and Description entered here can be used to identify the gate location Name Front Gates Description Front Gates This shows under the customers Automation App on the main display Ensure the wiring is complete refer to the w...

Page 15: ...isition the screen will change to the one shown here Select the button on the fob and it will add the button straight onto the control panel Set the safety inputs please refer to section 12 for options Select Next Select Calibrating Travel Once it has been accepted on the control panel It will display the above screen Enter a Name and select the correct function for the fob Select Save Repeat this...

Page 16: ...QR Code the app will open the devices camera enabling scanning of the QR code on the fobs packaging Once the QR code has been scanned enter a Name and select the correct function for each button on the fob If you wish for a certain button to not be active then untick the check box for that button Select Confirm Repeat this process for all fobs ...

Page 17: ...App On first login you will be prompted to accept the gateway You will then be presented with control options for your automation To transfer to a customer select the 3 dots Select Transfer site Enter customer details you wish to transfer to Select confirm The customer will get an email asking to confirm the account transfer to customer 2 name mycustomer co uk name mycustomer co uk Firstname Lastn...

Page 18: ...0 Exit the programming using the button 11 Check the gate operation by pulsing across connections 2 7 the gate will close Please refer to the main manual for Changing automatic closing time adjusting encoder settings if required Should the gates not operate as suggested above call CAME helpline 0115 921 0430 for technical support Safety inputs should now be configured and the gate force tested as ...

Page 19: ...g will be displayed Repeat the same procedure for adding another button A maximum of 1000 individual buttons can be saved remove a transmitter button 1 Press hold button Configuration is displayed 2 User management Delete single user 3 Select the transmitter button number to remove by using the keys and Confirm YES Repeat the same procedure to delete another transmitter button remove all transmitt...

Page 20: ...l commence once completed the automation will start closing the device C4 OBSTRUCTION WAIT When the automation is in either its opening or closing cycle and the safety circuit is triggered the automation will stop Once the safety is no longer triggered the automation will carry on the cycle it was performing at the time it was interrupted If during the reverse motion a different safety is triggered...

Page 21: ... sensitive safety edges as R7 two sensitive safety edges one pair sensitive safety edges with 8K2 resistor reopening when closing When the gate is closing opening the contact triggers the inversion of movement until the gate is fully open again R8 two sensitive safety edges one pair sensitive safety edges with 8K2 resistor reclosing when opening When the gate is opening opening the contact trigger...

Page 22: ...fit the replacement SIM card into the slot Replace the casing and power up the control panel Send an SMS to the telephone number of the SIM reporting the APN details Access Point Name ask the service provider for APN details e g APN pp vodafone co uk Capital lowercase letters and punctuation must be respected The SIM must be capable of 2G data transmission and have the PIN code disabled Full instr...

Page 23: ...DG Flush mounted 12 button Bus keypad with blue backlighting RAL7024 Grey colour TOP ROLLING CODE 8K06TS 001 TOPD4RXM 6 packaged dual frequency 4 button rolling code transmitters 4 294 967 896 combinations PHOTOCELLS Surface mounted Synchronised beam multiple pairs of photocells can be applied to the same system even at double height and or close to each other with no interference issues cross tal...

Page 24: ...orrect use of the Software requires the possession of an automation home automation security temperature control and or video surveillance system manufactured by Came which has been enabled for remote management 3 5 Any costs for connection via internet including telephone costs according to the rates applied by the operator chosen by the User himself herself are the sole responsibility of the Use...

Page 25: ...ation of the automation home automation security temperature control and or video surveillance system manufactured by Came may be associated with the system itself In this way the installer can perform remote diagnostics also verifying the number of operations performed the status of the photocells and the Hardware parameters and proceed with remote assistance to help the User 11 COMMUNICATION Any...

Page 26: ...ediate effect in the event of the violation of the terms of Articles 2 2 and or 2 5 In this case termination shall occur automatically upon receipt by the Installer of the notification sent by Came with no obligation for prior notice without prejudice to the right of Came to claim compensation for any damage suffered 6 PROVISION OF THE SERVICE LIMITATION OF LIABILITY 6 1 Came undertakes to ensure t...

Page 27: ...vidual parts of the additional network services and other related services referred to in Section 3 1 lit c of these GTC 1NCE expressly points out that the type and scope of such services of the respective mobile network operators in particular also the respective available transmission technologies e g no permanent use of 2G 3G in individual countries may vary and in addition individual available...

Page 28: ...on 2 of these GTC for the Services Within the framework of the conclusion of the contract the Customer may choose between different payment methods offered by 1NCE Unless otherwise agreed between the Parties the charges to be paid by the Customer for the purchase of additional Quotas in accordance with Section 3 3 sentence 2 of these GTC shall be determined by the price list of 1NCE valid at the t...

Page 29: ... Protection Act Bundesdatenschutzgesetz 10 2The Parties also undertake to treat all other confidential information of the other Party that the receiving Party becomes aware of in connection with the contractual relationship as strictly confidential and not to disclose such information to any third party for an unlimited period 10 31NCE uses the payment service provider Stripe Payments Europe Ltd The...

Page 30: ...notes ...

Page 31: ...notes ...

Page 32: ...a House Maxted Road Maylands Ind Est Hemel Hempstead Herts HP2 7DX Tel 01442 230 800 CAME BPT Ireland Unit 9 The Westway Centre Ballymount Dublin 12 Tel 353 0 1 450 7442 8K01MI 0523 QS0922 2022 EN YOU MAY NOT EVEN PARTIALLY REPRODUCE THIS DOCUMENT CAME RESERVES THE RIGHT TO MAKE ANY CHANGES TO THIS DOCUMENT AT ANY TIME THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT ...

Reviews: