4 x 1,5
2 x 1 - TX
4 x 1
2 x 1,5
3 x 1,5
2 x 1
- RX
T RG58
4 x 1,5
Pa
g
.
22
- M
an
u
al
c
od
e:
1
1
9
D
U
9
2
E
N
11
9
D
U
9
2
E
N
ver
.
2
2
0
1
/2
0
15 © C
A
M
E S
.p.
A
. - T
h
e d
at
a a
n
d i
n
fo
rm
at
io
n r
ep
or
te
d i
n t
h
is
in
st
al
la
ti
on
m
an
u
al
a
re s
u
sc
ep
ti
b
le t
o c
h
an
g
e a
t a
n
y t
im
e a
n
d without
obl
igation
on
C
A
M
E S
.p
.A
. to
notif
y user
s.
ENGLISH
Introduction
• Use this product only for the specifi c purpose for which it is designed. Any
other use is therefore improper and dangerous. CAME S.p.A. is not liable for
any damage due to improper, erroneous and unreasonable use • Keep these
warnings together with the installation and users' manual for the automation
system.
Before installing
(check what's there: if you fi nd something wrong, proceed only after correc-
ting the problem so the equipment is safe to use)
• Check that the part you want to automate is in good mechanical condition,
that it is balanced and aligned, and that it opens and closes properly. Make
sure you have suitable mechanical stops • If the operator will be installed less
than 2.5 m from the fl oor or from any other access level, check whether you
need additional protections and/ or warnings • With pedestrian doors framed
into the doors that will be automated, a system must be in place to block their
opening during movement • Make sure the opening of the automated door
leaf does not cause any trapping situations involving any surrounding fi xed
parts • Do not install the operator upside down or on any elements that may
bend. If necessary, add suitable reinforcements at the fastening points • Do
not install on sloping ground (only install on fl at ground) • Check that any
watering devices cannot wet the gearmotor from the bottom upwards.
Installation
• Properly signal and demarcate the entire site prevent any careless people
from entering the works area • Be careful when handling operators that wei-
gh more than 20 kg (see installation manual. If such is the case, make sure
you have proper hoisting equipment. All opening commands (buttons, key
selectors, magnetic card readers, and so on) must be installed at least 1.85
M from the gate's area of movement, or so that they are unreachable from
the outside. Moreover, the direct commands (from buttons, swipe cards, and
so on) must be installed 1.5 m high off the ground and must not be reachable
by the public • All "hold-to-run" commands must be placed where the ope-
rating gate leaves and transit areas are completely visible. • Apply a perma-
nent label that shows the position of the release device • Before turning over
the installation to the user, check that the system conforms to standards EN
12453 and EN12445 (impact testing), making sure the device has been pro-
perly adjusted and that the safety and protection and release devices function
properly • Where necessary apply the Warning Signs so that they are clearly
visible (e.g. the gate plate)
Instructions and special recommendations for users
• Keep the barrier's areas of operations unobstructed. Check that the photo-
cells are free of any vegetation blocking them, and that there are no obstacles
to the free movement of the operator. Do not allow children to play with the
fi xed command devices, or in the barrier's area of operation. Keep transmit-
ters and any other command devices away from children, to prevent the ope-
rator from being activated by mistake • Frequently check the system, to scan
for any anomalies or wear and tear in the moving structures, the operator's
components, all fastening points and devices, the cables and accessible con-
nections. Keep any jointed parts like hinges lubricated and clean of debris
and the guide-sleds free of any friction • Perform functional checks to the
photocells and sensitive edges every six months. To check that the photocells
work properly, wave an object in front of them during closing; if the operator
inverts its direction of travel or blocks movement, then the photocells are
working properly. This is the only maintenance job that can be done to the
gate when it is powered up. Ensure proper cleaning of the glass on the pho-
tocells (use a slightly damp cloth); do not use any solvents or other chemical
products that may ruin the devices) • Should any repairs or changes to the
system settings be needed, release the operator and refrain from using it until
safety conditions have been restored • Cut the power off before releasing the
operator for manual opening, to avoid any hazardous situations. Check in-
structions • It is FORBIDDEN for users to perform ANY OPERATIONS THAT ARE
NOT EXPRESSLY REQUESTED OF SAID USERS in the manuals. Any repairs,
adjustments or extra-ordinary maintenance, EXCLUSIVELY CALL TECHNICAL
ASSISTANCE • Log any service jobs onto the periodic maintenance journal.
Special instructions and recommendations for everyone
• Keep away from the hinges and any moving mechanical parts • Stay out
of the operating range of the operator while it is moving • Do not oppo-
se the movement of the operator as this may result in danger • Always be
careful around the dangerous parts, which must be properly indicated with
warning signs and black and yellow stripes • When using a selector switch or
a maintained-action mode command, keep checking that no persons come
within the operating range of the moving parts, until the command is released
• The gate may move at any moment without warning. Always cut off the
main electric power supply before performing any cleaning or maintenance.
WARNING!
important safety instructions:
READ CAREFULLY!
Hand crushing hazard
Danger high voltage
No transit during operation
Danger of crushing feet