Introduction

• Use this product only for the specifi c purpose for which it is designed. Any 
other use is therefore improper and dangerous. CAME S.p.A. is not liable for 
any damage due to improper, erroneous and unreasonable use • Keep these 
warnings together with the installation and users' manual for the automation 
system.

Before installing

(check what's there: if you fi nd something wrong, proceed only after correc-
ting the problem so the equipment is safe to use)

• Check that the part you want to automate is in good mechanical condition, 
that it is balanced and aligned, and that it opens and closes properly. Make 
sure you have suitable mechanical stops • If the operator will be installed less 
than 2.5 m from the fl oor or from any other access level, check whether you 
need additional protections and/ or warnings • With pedestrian doors framed 
into the doors that will be automated, a system must be in place to block their 
opening during movement • Make sure the opening of the automated door 
leaf does not cause any trapping situations involving any surrounding fi xed 
parts • Do not install the operator upside down or on any elements that may 
bend. If necessary, add suitable reinforcements at the fastening points • Do 
not install on sloping ground (only install on fl at ground) • Check that any 
watering devices cannot wet the gearmotor from the bottom upwards.

Installation

• Properly signal and demarcate the entire site  prevent any careless people 
from entering the works area • Be careful when handling operators that wei-
gh more than 20 kg (see installation manual. If such is the case, make sure 
you have proper hoisting equipment. All opening commands (buttons, key 
selectors, magnetic card readers, and so on) must be installed at least 1.85 
M from the gate's area of movement, or so that they are unreachable from 
the outside. Moreover, the direct commands (from buttons, swipe cards, and 
so on) must be installed 1.5 m high off  the ground and must not be reachable 
by the public • All "hold-to-run" commands must be placed where the ope-
rating gate leaves and transit areas are completely visible. • Apply a perma-
nent label that shows the position of the release device • Before turning over 
the installation to the user, check that the system conforms to standards EN 
12453 and EN12445 (impact testing), making sure the device has been pro-
perly adjusted and that the safety and protection and release devices function 
properly • Where necessary apply the Warning Signs so that they are clearly 
visible (e.g. the gate plate) 

Instructions and special recommendations for users

• Keep the barrier's areas of operations unobstructed. Check that the photo-
cells are free of any vegetation blocking them, and that there are no obstacles 
to the free movement of the operator. Do not allow children to play with the 
fi xed command devices, or in the barrier's area of operation. Keep transmit-
ters and any other command devices away from children, to prevent the ope-
rator from being activated by mistake • Frequently check the system, to scan 
for any anomalies or wear and tear in the moving structures, the operator's 
components, all fastening points and devices, the cables and accessible con-
nections. Keep any jointed parts like hinges lubricated and clean of debris 
and the guide-sleds free of any friction • Perform functional checks to the 
photocells and sensitive edges every six months. To check that the photocells 
work properly, wave an object in front of them during closing; if the operator 
inverts its direction of travel or blocks movement, then the photocells are 
working properly. This is the only maintenance job that can be done to the 
gate when it is powered up. Ensure proper cleaning of the glass on the pho-
tocells (use a slightly damp cloth); do not use any solvents or other chemical 
products that may ruin the devices) • Should any repairs or changes to the 
system settings be needed, release the operator and refrain from using it until 
safety conditions have been restored • Cut the power off  before releasing the 
operator for manual opening, to avoid any hazardous situations. Check in-
structions • It is FORBIDDEN for users to perform ANY OPERATIONS THAT ARE 
NOT EXPRESSLY REQUESTED OF SAID USERS in the manuals. Any repairs, 
adjustments or extra-ordinary maintenance, EXCLUSIVELY CALL TECHNICAL 

ASSISTANCE • Log any service jobs onto the periodic maintenance journal. 

Special instructions and recommendations for everyone

• Keep away from the hinges and any moving mechanical parts • Stay out 
of the operating range of the operator while it is moving • Do not oppo-
se the movement of the operator as this may result in danger • Always be 
careful around the dangerous parts, which must be properly indicated with 
warning signs and black and yellow stripes • When using a selector switch or 
a maintained-action mode command, keep checking that no persons come 
within the operating range of the moving parts, until the command is released 
• The gate may move at any moment without warning. Always cut off  the 
main electric power supply before performing any cleaning or maintenance. 

WARNING!

important safety instructions:

READ CAREFULLY!

Hand crushing hazard

Danger high voltage

No transit during operation 

Danger of crushing feet

Summary of Contents for A 3024

Page 1: ...INSTALLATION MANUAL A 3024 A 3124 A 5024 A 5124 AUTOMATION FOR SWING GATES English EN 119DU92EN ...

Page 2: ...afety and protection and release devices function properly Where necessary apply the Warning Signs so that they are clearly visible e g the gate plate Instructions and special recommendations for users Keep the barrier s areas of operations unobstructed Check that the photo cells are free of any vegetation blocking them and that there are no obstacles to the free movement of the operator Do not al...

Page 3: ...scription 2 1 Intended use 1 Legend of symbols This symbol tells you to read the section with particular care This symbol tells you that the sections concern safety issues This symbol tells you what to say to the end users 2 Intended use and restrictions The ATI 24V gearmotor is specifically engineered to automate residential and condominium swing gates even under intensive use 3 Reference Standard...

Page 4: ...e the path of the electrical cables complies with the command and safety instructions That there is a soundly secured to the ground mechanical stop to prevent the gate leaf gearmotor from over extending Make sure that any connections inside the case that provide continuance to the protective circuit be fitted with extra insulation as compared to the other conductive parts inside Make sure you have...

Page 5: ...0204 1 For connections that require several sequential loads the sizes given on the table must be re evaluated based on actual power draw and distances 5 3 Cable list and minimum thickness Connections Type of cable Length of cable 1 10 m Length of cable 10 20 m Length of cable 20 30 m Control panel power supply 230V FROR CEI 20 22 CEI EN 50267 2 1 3G x 1 5 mm2 3G x 2 5 mm2 3G x 4 mm2 Flashing ligh...

Page 6: ...has several other holes for changing the opening angle of the gate N B increasing the B measurement decreases the opening angle resulting in slower peripheral speed and greater motor thrust on the gate leaf Increasing measurement A increases the opening angle resulting in greater peripheral speed and reduced motor thrust on the gate leaf With the gate closed apply the anchoring plate to the gate l...

Page 7: ...ve the stem N B we suggest lubricating using neutral grease the endless screw and the bushing upon installation Begin mounting the gearmotor to the two brackets M8 self locking nut Endless screw Carter Stem Motor terminal block Control panel terminal block Motor 1 N1 M1 C Fa1 Rc1 C Ra1 Motor 2 N2 M2 C Fa2 Rc2 C Ra2 ZL 19N N M Connection to motor F Fa Microswitch limit switch of motor on aperture R...

Page 8: ...croswitch unit actuation runner Fix the microswitches unit by tightening the respective screws DURING CLOSURE Move the wing to no closer than 100 mm from the end stop during closure detail B Unscrew the fixing screws of the group deceleration microswitch during closure Slide the microswitch unit along the microswitch support rod until it is inserted by contact on the microswitch unit actuation runn...

Page 9: ...ull the gate manually To re lock the gate simply insert and turn the key 5 9 Personalized key release Access door Key Release the gearmotor and move the door to the maximum desired open position Loosen the fixing screws of the microswitch unit Slide the microswitch unit along the microswitch support rod until it is inserted by contact on the microswitch unit actuation runner Fix the microswitch by ...

Page 10: ...nght of A and B see Tab 4 Attach the rear bracket together with a supplementary bracket and fasten both to the column Open the gate maximum 90 and measure E see Tab 4 then fasten the front bracket to the gate Make the electrical connections as shown in the figure Re position and adjust the opening micro switch Motor terminal block Control panel terminal block Motor 1 Motor 2 7 Manutenzione 7 1 Manu...

Page 11: ...flasher does not work The bulb is burnt Call assistance 8 Maintenance Date Notes Signature Periodic maintenance log for end user every 6 moths 8 1 Extra ordinary maintenance The following table serves to note down any extraordinary maintenance repairs or improvements performed by specialised firms N B Any extraordinary maintenance must be performed by specialised technicians Extra ordinary mainten...

Page 12: ...performed _______________________________________________________________________________________ __________________________________________________________________________________________________ _ CAME S p A employs a UNI EN ISO 14001 certified and compliant environmental protection system at its plants to ensure that environmental safeguarding We ask you to keep protecting the environment as CA...