ATS50AGS: 

GEOMETRY

•  The greater the motor angle, the greater 

the opening speed and the slower the 

gear motor’s thrust.

•  The smaller the motor angle, the slower 

the opening speed and the greater the 

gear motor’s thrust.

•  Lubricate the bushing and fit it into one of the holes on the post bracket.

•  The bracket holes allow the opening angle to be changed.

Opening

A (mm)

B (mm)

E (mm)

F (mm)

C max. (mm)

90

°

200

200

1030

1430

150

90

°

200

270

1030

1510

200

120

°

200

140

1030

1460

70

Preliminary checks

Side hung gate GEOMETRY 

(5m)

  

Tick

1.  Check that the gate structure is sturdy enough, the hinges work efficiently and that there is  

no friction between the fixed and moving parts

 

2.  Make sure that measurement 

C

 does not exceed the value shown in the reference table

 

3.  Make sure that you have fitted opening and closing mechanical gate stops 

 

OUTward OPENING gates

For outward opening gate geometry  

please refer to the full Installation Manual.

A

C

B

60

60

E

F

Summary of Contents for ATS-S5 KIT

Page 1: ... GUIDE Typical gate setup geometry Gate motor manual release Kit wiring diagram Control panel guide safety Complete kit for a single swing gate weighing up to 400kg max width 5m TO BE READ IN CONJUNCTION WITH THE FULL INSTRUCTION MANUAL ...

Page 2: ...xed code Transmitter ATS50AGS Motor x2 ATS S5 KIT CONTENTS 1 Kit Contents 2 Safety Instructions 3 Typical Gate Setup 4 Geometry 5 Manual Release Instructions 6 Kit Wiring Diagram 7 Control Panel Quick Start Guide 8 Control Panel Programming Transmitters 9 Connect Setup 10 Control Panel Safety 11 Optional Accessories ...

Page 3: ...ssing through the gate Keep feet away from the bottom of the gate during operation Do not operate the gate by remote control unless they are in view Do not attempt to block or interfere with the gate movement during operation Under no circumstances should you attempt to modify the gate automation system Ensure that your gate is serviced at 3 to 12 month intervals dependent on number of openings by...

Page 4: ... glands to connect the devices to the control panel One of these must be used exclusively for the power supply cable All holes should be sealed to avoid ingression and maintain the IP54 protection rating Only a competent service provider should open the enclosure and adjust the settings The photocells are used in pairs one transmitter and one receiver They should be installed between 500 600mm fro...

Page 5: ... mm F mm C max mm 90 200 200 1030 1430 150 90 200 270 1030 1510 200 120 200 140 1030 1460 70 Preliminary checks Side hung gate GEOMETRY 5m Tick 1 Check that the gate structure is sturdy enough the hinges work efficiently and that there is no friction between the fixed and moving parts 2 Make sure that measurement C does not exceed the value shown in the reference table 3 Make sure that you have fi...

Page 6: ...carefully at the same speed as the automatic operator 4 To re engage close the gate and turn the key back to its original position D Attempt to manually move the gate to ensure it is fully engaged Basic Maintenance Hints Tips Open manual release cover spray locking mechanism with suitable penetrating lubricant Lubricate gate hinges Manually release the gates at least once per month ALWAYS isolate ...

Page 7: ... 10 2 TX C NC TX 2 RX TX DIR Photocells Cable length RX 4 Core 0 5mm Flex TX 4 Core 0 5mm Flex 1m 30m ATS50AGS Gate motor Cable length 1m 20m 3 Core 1 5mm 20m 30m 3 Core 2 5mm AF43S Plug in TOP A433N Antenna Cable length RG58 Max 5m Mains Supply 230 V AC Cable length 1m 20m 3 Core 1 5mm 20m 30m 3 Core 2 5mm The Earth cable should be connected to the motor chassis ...

Page 8: ...e gate to its closed position Send a closing command pulse using a link wire between terminal 2 4 While the motor is running turn the rod marked C anticlockwise until the motor stops running Set the gates to its open positions Send an opening command pulse using a link wire between terminal 2 3 While the motor is running turn the rod marked A clockwise until the motor stops running Note 20 complet...

Page 9: ...r The PROG LED goes solid to signal the successful saving of the code 3 Release the CH1 key A maximum of 25 individual buttons can be saved remove all transmitters 1 Press and hold the CH1 and CH2 buttons simultaneously until the PROG LED stays lit All previously saved transmitter buttons will be removed from the memory of the control board 1 S 1 2 3 3P 4 5 7 2 C1 CX B1 B2 2 FC1 FA2 FC2 FA1 10 11 ...

Page 10: ...ill stop and reverse its motion until it reaches its fully closed position again Once the automation has reached the fully closed position it will require another activation from a command device to restart CX PARTIAL STOP When the automation is in its opening cycle and the safety circuit is triggered the automation will stop If the auto closing option is enabled and the safety is no longer trigge...

Page 11: ...ur 806SL 0250 SELB1SDG3 Surface mounted with blue backlighting for 250 users RAL7024 Grey colour HARDWIRED KEYPAD SELECTORS 806SL 0280 SELT1BDG Surface mounted 12 button Bus keypad with blue backlighting RAL7024 Grey colour 806SL 0290 SELT2BDG Flush mounted 12 button Bus keypad with blue backlighting RAL7024 Grey colour 806SL 0370 S0002P External two channel 12 24 V AC DC IP54 control card for key...

Page 12: ...THIS DOCUMENT AT ANY TIME THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT OBLIGATION TO GIVE PRIOR NOTICE BY CAME S P A E OE CAME BPT North Unit 1B Sills Road Willow Farm Business Park Castle Donington DE74 2US Tel 0115 921 0430 CAME BPT South Liberta House Maxted Road Maylands Ind Est Hemel Hempstead Herts HP2 7DX Tel 01442 230 800 CAME BPT Ireland Unit 9 The Westwa...

Reviews: