background image

ZA3P: 

QUICK START GUIDE 

Should the gates not operate as suggested above,

call CAME helpline 

0115 921 0430

 for technical support.

Important!

Ensure the wiring is complete (refer to the wiring diagram) & any required physical stops are set before 

commencing with programming

 

Tick

1.  Power on the control panel. 

2.  Disable total stop – Permanent link wire between terminal 

1

 & 

2

3.  If no safety device has been connected to the 

C1

 terminal then disable the safety input 

C1

 - 

Permanent link wire between terminal 

2

 & 

C1

.  

4.  Disable safety input 

CX

 – Dip switch 

8

 on. 

5.  Set all other dip switches off. 

6.  Check the motor direction 
 

Enable maintained action – Dip switch 

6

 on. 

 

Hold a wire between terminal 

2

 & 

3

.

 

The gate should open, if not reverse the motor cables for motor 2 (Connections X, Y)

 

Disable maintained action – Dip switch 

6

 off

7.  Set the ATS microswitch end stops 
 

Unlock the motor on the manual release

 

Adjust the TL potentiometer to the maximum clockwise position.

 

Set the gate to its closed position

 

     Send a closing command pulse using a link wire

 

     between terminal 

2

 & 

4

.

 

     While the motor is running, turn the rod marked 

C

 

 

     anticlockwise until the motor stops running.

 

Set the gates to its open positions

 

     Send an opening command pulse using a link wire between 

 

     terminal 

2

 & 

3

.

 

     While the motor is running, turn the rod marked 

A

 

 

     clockwise until the motor stops running.

  
 

Note. 20 complete turns of the rod is equal to 10mm of movement of the micro switch. By default the motor run time is set to 120s, if the 

motor times out before the micro switch has been reached an additional command will need to be sent to start the motor running again 

so that the micro switch setup can be completed.

8.  Set the TRM2 potentiometer all the way to minus (Anticlockwise). 

9.  Adjust the TL potentiometer to the 4 O’clock position 

10.  Check the gate operation by pulsing across connections 

2

 & 

4

, the gate will close. 

Safety inputs should now be configured and the gate force tested as required. 
Please refer to the full manual to complete the commissioning.

Potentiometers Dip Switches

The installation must be carried out 

by skilled and qualified personnel

ZA3P: 

transmitters 

Should the transmitter not operate as suggested above,

call CAME helpline 

0115 921 0430

 for technical support.

add

 a transmitter button

1. 

Press and hold the 

CH1

 button, the 

PROG. LED

 starts fl ashing rapidly.

 

2. 

While keeping the 

CH1

 button held down press and release a button on a transmitter

 

 The 

PROG. LED

 goes solid to signal the successful saving of the code.

3. 

Release the 

CH1

 key.

 

A maximum of 25 individual buttons can be saved.

remove

 all transmitters

1. 

Press and hold the 

CH1

 and 

CH2

 buttons simultaneously until the 

PROG. LED 

stays lit

 

 

All previously saved transmitter buttons will be removed from the memory of the control board.

L N

U V W X Y E E3

10 11 S 1 2 3 3P 4 5 7

2 C1 CX B1 B2

TS 10

L1T

CT

0 12 24

L2T

2

FC1 FA2 FC2

FA1

L2T

L1T

1

2

3

4

0 12 24

 

L N

U V W X Y E E3

10 11 S 1 2 3 3P 4 5 7

2 C1 CX B1 B2

TS 10

L1T

CT

0 12 24

L2T

2

FC1 FA2 FC2

FA1

L2T

L1T

1

2

3

4

0 12 24

 

Ensure the AF card is fi tted (refer to the wiring diagram).

Summary of Contents for ATS-S5 KIT

Page 1: ... GUIDE Typical gate setup geometry Gate motor manual release Kit wiring diagram Control panel guide safety Complete kit for a single swing gate weighing up to 400kg max width 5m TO BE READ IN CONJUNCTION WITH THE FULL INSTRUCTION MANUAL ...

Page 2: ...xed code Transmitter ATS50AGS Motor x2 ATS S5 KIT CONTENTS 1 Kit Contents 2 Safety Instructions 3 Typical Gate Setup 4 Geometry 5 Manual Release Instructions 6 Kit Wiring Diagram 7 Control Panel Quick Start Guide 8 Control Panel Programming Transmitters 9 Connect Setup 10 Control Panel Safety 11 Optional Accessories ...

Page 3: ...ssing through the gate Keep feet away from the bottom of the gate during operation Do not operate the gate by remote control unless they are in view Do not attempt to block or interfere with the gate movement during operation Under no circumstances should you attempt to modify the gate automation system Ensure that your gate is serviced at 3 to 12 month intervals dependent on number of openings by...

Page 4: ... glands to connect the devices to the control panel One of these must be used exclusively for the power supply cable All holes should be sealed to avoid ingression and maintain the IP54 protection rating Only a competent service provider should open the enclosure and adjust the settings The photocells are used in pairs one transmitter and one receiver They should be installed between 500 600mm fro...

Page 5: ... mm F mm C max mm 90 200 200 1030 1430 150 90 200 270 1030 1510 200 120 200 140 1030 1460 70 Preliminary checks Side hung gate GEOMETRY 5m Tick 1 Check that the gate structure is sturdy enough the hinges work efficiently and that there is no friction between the fixed and moving parts 2 Make sure that measurement C does not exceed the value shown in the reference table 3 Make sure that you have fi...

Page 6: ...carefully at the same speed as the automatic operator 4 To re engage close the gate and turn the key back to its original position D Attempt to manually move the gate to ensure it is fully engaged Basic Maintenance Hints Tips Open manual release cover spray locking mechanism with suitable penetrating lubricant Lubricate gate hinges Manually release the gates at least once per month ALWAYS isolate ...

Page 7: ... 10 2 TX C NC TX 2 RX TX DIR Photocells Cable length RX 4 Core 0 5mm Flex TX 4 Core 0 5mm Flex 1m 30m ATS50AGS Gate motor Cable length 1m 20m 3 Core 1 5mm 20m 30m 3 Core 2 5mm AF43S Plug in TOP A433N Antenna Cable length RG58 Max 5m Mains Supply 230 V AC Cable length 1m 20m 3 Core 1 5mm 20m 30m 3 Core 2 5mm The Earth cable should be connected to the motor chassis ...

Page 8: ...e gate to its closed position Send a closing command pulse using a link wire between terminal 2 4 While the motor is running turn the rod marked C anticlockwise until the motor stops running Set the gates to its open positions Send an opening command pulse using a link wire between terminal 2 3 While the motor is running turn the rod marked A clockwise until the motor stops running Note 20 complet...

Page 9: ...r The PROG LED goes solid to signal the successful saving of the code 3 Release the CH1 key A maximum of 25 individual buttons can be saved remove all transmitters 1 Press and hold the CH1 and CH2 buttons simultaneously until the PROG LED stays lit All previously saved transmitter buttons will be removed from the memory of the control board 1 S 1 2 3 3P 4 5 7 2 C1 CX B1 B2 2 FC1 FA2 FC2 FA1 10 11 ...

Page 10: ...ill stop and reverse its motion until it reaches its fully closed position again Once the automation has reached the fully closed position it will require another activation from a command device to restart CX PARTIAL STOP When the automation is in its opening cycle and the safety circuit is triggered the automation will stop If the auto closing option is enabled and the safety is no longer trigge...

Page 11: ...ur 806SL 0250 SELB1SDG3 Surface mounted with blue backlighting for 250 users RAL7024 Grey colour HARDWIRED KEYPAD SELECTORS 806SL 0280 SELT1BDG Surface mounted 12 button Bus keypad with blue backlighting RAL7024 Grey colour 806SL 0290 SELT2BDG Flush mounted 12 button Bus keypad with blue backlighting RAL7024 Grey colour 806SL 0370 S0002P External two channel 12 24 V AC DC IP54 control card for key...

Page 12: ...THIS DOCUMENT AT ANY TIME THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT OBLIGATION TO GIVE PRIOR NOTICE BY CAME S P A E OE CAME BPT North Unit 1B Sills Road Willow Farm Business Park Castle Donington DE74 2US Tel 0115 921 0430 CAME BPT South Liberta House Maxted Road Maylands Ind Est Hemel Hempstead Herts HP2 7DX Tel 01442 230 800 CAME BPT Ireland Unit 9 The Westwa...

Reviews: