Gearmotor for swing gates
ATS30AGS
ATS50AGS
ATS30AGR
ATS50AGR
INSTALLATION MANUAL
FA01337-EN
EN English
Page 1: ...Gearmotor for swing gates ATS30AGS ATS50AGS ATS30AGR ATS50AGR INSTALLATION MANUAL FA01337 EN EN English...
Page 2: ...1 2 3 1 2 3 4...
Page 3: ...upply that is compliant with the installation rules It should completely cut off the power supply according to category III surcharge conditions Demarcate the entire site properly to prevent unauthori...
Page 4: ...egies Simply follow these brief disposal guidelines DISPOSING OF THE PACKAGING The packaging materials cardboard plastic etc can be disposed of easily as solid urban waste separated for recycling Befo...
Page 5: ...ed are in millimetres Description 801MP 0050 ATS30AGS Irreversible telescopic gearmotor 230 V for swing gates with Max C 200 mm with leaf up to 3 m and 400 kg Grey RAL7024 801MP 0060 ATS50AGS Irrevers...
Page 6: ...otor 1 Gate bracket 2 Door to access the end of travel adjustment screws 3 Door to access the release mechanism 4 Sheath connector 5 Post bracket 6 Release key 7 Release cord 8 Cutting hazard labels A...
Page 7: ...erating cycles MODELS ATS30AGS ATS50AGS ATS30AGR ATS50AGR Cycles hour no 20 20 20 20 Consecutive cycles no 10 10 10 10 The cycles calculation applies to gates that are professionally installed free of...
Page 8: ...r fitting the operator and accessories varies depending on the area where it is installed It is up to the installer to find the most suitable solution The drawings refer to a gearmotor installed on th...
Page 9: ...o 90 or 120 First determine where the gate bracket needs to be positioned then where the post bracket needs to be positioned Respect the values indicated in the table A C B 60 60 E F 5 ATS30AGS ATS30A...
Page 10: ...riginal instructions Fastening the brackets Secure the post bracket with plugs and screws If the post is made of metal the post bracket must be welded to it The holes on the bracket fixing plate allow...
Page 11: ...at any time and without notice Translation of the original instructions Fastening the gearmotor Lubricate all moving parts on the operator A The self locking nut must be loosely tightened so as not t...
Page 12: ...ons ELECTRICAL CONNECTIONS Before working on the control panel disconnect the mains power supply and remove the batteries if any Remove the protective cover to access the terminal board A Control pane...
Page 13: ...roswitch 10 mm in either direction turn the rod 20 times Determining the opening end of travel points Release the gearmotor Open the gate manually Send an opening command At the same time turn the rod...
Page 14: ...hing the bracket fastening points Close the gate manually First determine where the gate bracket needs to be positioned then where the post bracket needs to be positioned Respect the values indicated...
Page 15: ...ons Electrical connections Before working on the control panel disconnect the mains power supply and remove the batteries if any Remove the protective cover to access the terminal board A Control pane...
Page 16: ...d of travel points Release the gearmotor Open the gate manually Send an opening command At the same time turn the rod for determining the opening end of travel point ANTICLOCKWISE until the gearmotor...
Page 17: ...p 17 Manual FA01337 EN 11 2019 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions FINAL OPERATIONS 1 2...
Page 18: ...f the system is not used for long periods of time e g for installations at sites with seasonal closures disconnect the power supply When the power supply is reconnected check the system is working cor...
Page 19: ...CONTROL PANEL FOR 120 V OR 230 V GEARMOTORS ZF1N110 ZF1N INSTALLATION MANUAL EN English FA00679 EN...
Page 20: ...s manual is forbidden Technical data Type ZF1N ZF1N110 Protection rating IP 54 Power supply V 50 60 Hz 230 AC 120 AC Input voltage motor V 230 AC 120 AC Consumption in stand by mode mA 40 Maximum powe...
Page 21: ...pliant with the installation rules It should completely cut off the power supply according to category III surcharge conditions make sure that any connections inside the container ones that ensure con...
Page 22: ...2 x 0 5 mm 2 Command and control devices 2 x 0 5 mm 2 Safety devices 2 x 0 5 mm 2 When powered at 120 V or 230 V and used outdoors use H05RN F type cables that comply with 60245 IEC 57 IEC whereas in...
Page 23: ...astening the control panel Fasten the control panel in a protected area using suitable screws and dowels Only use 6 x 70 mm cylinder head screws Drill through the pre drilled holes 18 and 20 mm under...
Page 24: ...nual may be changed at any time and without notice 120 V AC version if available Motor s torque limiter To vary the motor torque move the faston as shown to one of the four positions 1 min 4 max Gearm...
Page 25: ...ed Output for connecting the ashing signal light Contact rated for 120 V or 230 V AC 25 W max Signaling devices Electrolock connection at 12 V Maximum power 15 W Electric lock OPEN CLOSE INVERT functi...
Page 26: ...g the safety devices i e the safety test At each opening and closing command the control board checks the efficacy of the safety devices such as photocells Any anomalies will inhibit all commands For...
Page 27: ...4 OFF Deactivated Settings Functions Trimmer Description of functions A C T AUTOMATIC CLOSING TIME It sets the open gate s waiting time Once this time elapses a closing maneuver is automatically perfo...
Page 28: ...ing LED ashing Press any key on the transmitter you want to memorize The LED stays on to indicate thatmemorization has been successful AF card MANAGING USERS BY RADIO CONTROL Preliminary operations Co...
Page 29: ...verage length ashes about 5 seconds and quick ashes about 2 seconds until it it switches off Reset DIP switch 4 to OFF Programming LED PROG key Deleting a single user Set DIP switch 4 to ON Keep press...
Page 30: ...ure you comply with local laws before dismantling and disposing of the product The packaging materials cardboard plastic and so on should be disposed of as solid household waste and simply separated f...