p.
21
- M
anu
al
FA
0
1
2
0
8
-E
N
- 0
7/
2
0
21 - © C
A
M
E S
.p
.A
. - T
ransla
te
d o
riginal inst
ru
ct
io
ns
F56
Peripheral number
To set the peripheral number from 1 to 255 for each control board when a system is fi tted with several
operators and features the CRP (Came Remote Protocol) connection system.
1 ----> 255
F63
COM speed
For setting the communication speed used in the CRP (Came Remote Protocol) connection system.
0
= 1200 Baud /
1
= 2400 Baud /
2
= 4800 Baud /
3
= 9600 Baud /
4
= 14400 Baud /
5
= 19200 Baud
/
6
= 38400 Baud (
default
) /
7
= 57600 Baud /
8
= 115200 Baud
F65
Wireless input
RIO-EDGE [T1]
RIO-EDGE wireless safety device associated to a function of choice among those available: P0= stop gate and
exclude any automatic closing; to resume movement, use the control device, P7 = reopening during closing,
P8 = reclosing during opening.
For programming, see the instructions that come with the accessory.
This function only appears is the control board has been fi tted with a RIO-CONN card.
OFF (default) / P0
= P0
/ P7
= P7
/ P8
= P8
F66
Wireless input
RIO-EDGE [T2]
RIO-EDGE wireless safety device associated to a function of choice among those available: P0= stop gate and
exclude any automatic closing; to resume movement, use the control device, P7 = reopening during closing,
P8 = reclosing during opening.
For programming, see the instructions that come with the accessory.
This function only appears is the control board has been fi tted with a RIO-CONN card.
OFF (default) / P0
= P0
/ P7
= P7
/ P8
= P8
F67
Wireless input
RIO-CELL [T1]
RIO-CELL is associated to any function chosen among those available: P1 = reopening during closing; P2 =
reclosing during opening; P3 = partial stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.
This function only appears is the control board has been fi tted with a RIO-CONN card.
OFF (default) / P1
= P1
/ P2
= P2
/ P3
= P3 /
P4
= P4
F68
Wireless input
RIO-CELL [T2]
RIO-CELL is associated to any function chosen among those available: P1 = reopening during closing; P2 =
reclosing during opening; P3 = partial stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.
This function only appears is the control board has been fi tted with a RIO-CONN card.
OFF (default) / P1
= P1
/ P2
= P2
/ P3
= P3 /
P4
= P4
F71
Partial opening time
After an opening command from the button connected to 2-3P, the gate opens for an adjustable time of
between fi ve seconds and 40 seconds.
This function only appears is the Encoder function is deactivated.
5
= 5 Seconds (
default
) /... /
40
= 40 Seconds
U1
Entering users
Entering up to 250 users and associating to each one a function of choice among those included. Use a
transmitter or other control device to enter the data (see paragraph called ENTERING A USER WITH AN
ASSOCIATED COMMAND).
1
= Step-step command (open-close) /
2
= Sequential command (open-stop-close-stop) /
3
= Open only
command /
4
= Partial opening command
U2
Deleting users
Deleting single users (see paragraph called DELETING SINGLE USERS)
U3
Deleting users
Deleting all users.
0
= Deactivated (
default
) /
1
= Delete
U4
Decoding the code
Select the type of transmitter radio coding that you wish to save on the control board.
⚠
When you select a radio coding, all saved transmitter are automatically deleted.
TWIN's coding lets you save multiple users with the same key (Key block).
1
= all (
default
) /
2
= Rolling Code /
3
= TWIN
A4
Resetting parameters
Caution! The default settings will be restored.
OFF
(
default
) /
ON
A5
Maneuver count
For viewing the number of maneuvers made by the gate.
H1
Version
View the fi rmware version.