background image

1

2

2

1

5

3

4

3

PSAP08

PSAP08

1

2

3

Pa

g

1010

  - M

an

u

al

 c

od

e: 

11

9

G

3

7

8

4

E

N

11

9

G

3

7

8

4

E

N

 ve

r.

 

2

  

2  

0

2

/2

0

14  © C

A

M

E

 c

an

ce

lli

 auto

m

ati

ci

 S

.p.

A

. - T

h

e d

ata a

n

d i

n

fo

rm

ati

on p

rovi

d

ed

 in

 th

is

 m

an

u

al

 a

re s

u

b

je

ct to c

h

an

g

e at a

ny ti

m

e w

ith

ou

t p

ri

or n

oti

ce

 by C

A

M

E

 C

an

ce

lli

 A

u

to

m

ati

ci

 S

.p.a.

FINAL OPERATIONS

Proper adjustment of the hydraulic damper is a necessary condition for the correct turnstile operation with reduction of mechanical stress on the system.

Both the working temperature and duty cycle must be taken into account to properly adjust the hydraulic damper.

 Remove line voltage during installation and make sure that the tripod moves freely.

Loosen the nut.

❷ 

Acting on the tripod, perform simulated use and, while screwing/unscrewing the damper, adjust braking force of the rotating mechanism: it must smoothly 

reach the end run during deceleration.

 Make sure that slowdown is as expected for both clockwise and anti-clockwise rotation.

 Lock the hydraulic damper by tightening the nut.

ADJUSTING THE HYDRAULIC DAMPER

 Make sure that the hydraulic damper is correctly adjusted (see specific chapter).

Mount the side casings 

 

. Lower the lid

 

and pull it back slightly 

. Close the lock using the key 

.

Summary of Contents for BRIDGE PSAP01

Page 1: ...INSTALLATION MANUAL English EN TRIPOD TURNSTILES BRIDGE PSAP01 PSAP07N PSAP08 119G3784EN...

Page 2: ...1 5 m and must not be accessible to the public The turnstile identi cation data must be clearly visible Before connecting the turnstile to the power supply make sure the identi cation data correspond...

Page 3: ...pod release in the event of a blackout 001PSAP08 Two way mechanical turnstile in galvanised painted steel RAL 7035 complete with control board hydraulic damper and LED direction arrows Automatic tripo...

Page 4: ...tal casing 4 Housing 5 Top cover 6 Mechanism 7 TOR100A control panel 8 Cover lock 9 Screws and washers for fixing the legs to the casing Dimensions Example of a system 1 Tripod turnstile 2 Direction a...

Page 5: ...o the actual current draw of the devices connected and according to the provisions of the IEC EN 60204 1 standard For connections that require several sequential loads the sizes given on the table mus...

Page 6: ...turnstile Open the lock using the key lift the cover and slightly pull it forward while pulling it upwards Lift the casings and remove them Attach the arms to the head of the tripod with screws M10x60...

Page 7: ...d Once you have determined the location use a pencil to mark the drill holes according to the dimensions indicated mm Place the turnstile over the wall dowels If present the corrugated conduit for the...

Page 8: ...e cables and Ref Description L1T White L2T Red Black isolated Ref Description L1T White Red isolated L2T Black Replace the 1 6A line fuse with a 3 15 A unit Operations reserved for the installing tech...

Page 9: ...08 PSAP07N PSAP07N Stop button N C contact Blocks the turnstile Anti clockwise operation button N O contact Allows anti clockwise unlocking of the tripod The tripod will lock automatically after a xed...

Page 10: ...t be taken into account to properly adjust the hydraulic damper Remove line voltage during installation and make sure that the tripod moves freely Loosen the nut Acting on the tripod perform simulated...

Page 11: ...rvice Restore the spring Check the contact The turnstile remains locked The free direction cam is incorrectly positioned or damaged The person going through leaned on the arm before it was released Bo...

Page 12: ...nd other relevant provisions established in Directives 2006 95 EC and 2004 108 EC A true copy of the declaration of conformity is available upon request DISMANTLING AND DISPOSAL CAME CANCELLI AUTOMATI...

Reviews: