MAINTENANCE
Before any maintenance, disconnect line voltage to prevent any possible dangerous situations that can be caused by accidental movement.
For proper maintenance of steel, please consult the manual 119RW48 on steel cleaning operations.
Periodic maintenance
Model
Operating Limits
MCBF
PSAP01
Maximum number of daily cycles: 15,000
Maximum number of cycles per minute: 12 (1 cycle every 5 seconds)
1,500,000
PSAP07N
PSAP08
PROBLEMI
POSSIBLE CAUSES
CHECKS AND REMEDIES
PSAP01 PSAP07N PSAP08
The turnstile
remains unlocked
in both directions
• The free direction cam is incorrectly positioned or
damaged
• No power
• Emergency or release button pressed
• Electric locks out of order
• Check the position, replace the cam
• Check for mains power
• Reset the emergency button or release button
• Contact service
㾎
㾎
㾎
㾎
㾎
㾎
㾎
The turnstile
unlocks only in one
direction
• One of the electric locks is out of order
• The spring of one of the electric locks has come
unlatched
• Button 2-3 or 2-4 is pressed
• Contact service
• Restore the spring
• Check the contact
㾎
㾎
㾎
㾎
㾎
㾎
The turnstile
remains locked
• The free direction cam is incorrectly positioned or
damaged
• The person going through leaned on the arm
before it was released.
• Both electric locks remain energised
• Stop button active
• Check the position, replace the cam
• Ask the person to stand free of the arm and try
unlocking again
• Contact service
• Check the release command validity
㾎
㾎
㾎
㾎
㾎
㾎
㾎
The tripod fails to
slowdown at end
run
• The hydraulic damper is out of order
• • Adjust the hydraulic damper
㾎
㾎
㾎
The turnstile
remains unlocked
after passing
through it
• The entrance/exit sensor is positioned incorrectly
• The entrance/exit sensor is out of order
• Check the position of the entrance/exit sensor
• Contact service
㾎
㾎
㾎
㾎
TROUBLESHOOTING
Every 400,000 cycles and at least every 6 months:
1.
Check turnstile internal wiring and verify that there are no loose or damaged cables.
2. Check that there are no abnormal movements and that rotation is smooth by turning the tripod. Any sudden locking could be a sign of malfunction.
3. Check that turnstile is securely fi xed to the ground by trying to move it; poor ground anchoring could lead to danger.
4. Check bolt tightness.
5. Check hydraulic damper adjustment.
6. Check the effi ciency of lock/release levers.
7. Linear rail cleaning/lubrication.
8. Check roller condition.
Each 1,000,000 cycles, replace:
9. Rollers and electric locks.
Each 3,000,000 cycles, replace:
10. Runner springs.