6.5 Motor torque limiter
To change the torque, move the faston identifi ed by the
black wire (connected to the CT terminal) to one of four
positions: 1 min ÷ 4 max.
6.4 Gearmotor end-stop connection
Gearmotor end-stop assembly already connected for
installation on the left-hand side seen from inside.
For right-hand installation:
- reverse FA-FC of the end stops on the terminal board;
- reverse the U-V phases of the motor on the terminal board.