ON
OFF
/.
LINE
LINE
FUSE
FUSE
ON
ON
2
1
3 4 5 6 7 8 9 10
10
L1T
L1T L2T
L2T CT
CT
VS
VS
VF
VF
U
V
W
E1
E1
L
N
24
24
12
12
0
10
10
11
11
TS
TS
1
2
3
3P
3P
4
7
C1
C1
C3
C3
EB
EB EB
EB
FC
FC
FA
FA
F
+ A. C. -
+ A. C. -
+ PAR.OP -
+ PAR.OP -
ELECTRIC
ELECTRIC
BLOCK
BLOCK
1.6A
1.6A
BOARD 315mA
BOARD 315mA
ACCESSORIES
ACCESSORIES
1A
1A
BATTERY 1.6A
BATTERY 1.6A
CONTROL
CONTROL
BOARD
BOARD
ZBK8
ZBK8
AF1
AF1
AF2
AF2
CH1
CH1
-
+
LINE
LINE
FUSE
FUSE
ON
ON
2
1
3 4 5 6 7 8 9 10
10
L1T
L1T L2T
L2T CT
CT
VS
VS
VF
VF
U
V
W
E1
E1
L
N
24
24
12
12
0
10
10
11
11
TS
TS
1
2
3
3P
3P
4
7
C1
C1
C3
C3
EB
EB EB
EB
FC
FC
FA
FA
F
+ A. C. -
+ A. C. -
+ PAR.OP -
+ PAR.OP -
ELECTRIC
ELECTRIC
BLOCK
BLOCK
1.6A
1.6A
BOARD 315mA
BOARD 315mA
ACCESSORIES
ACCESSORIES
1A
1A
BATTERY 1.6A
BATTERY 1.6A
CONTROL
CONTROL
BOARD
BOARD
ZBK8
ZBK8
AF1
AF1
AF2
AF2
CH1
CH1
-
+
Pa
g.
1717
- M
an
u
al
c
od
e:
11
9
B
T
8
5
11
9
B
T
8
5
ve
r.
2
04/
2
0
14 © C
A
M
E c
an
ce
lli
auto
m
ati
ci
s.p.a. - T
h
e d
ata a
n
d i
nf
or
m
ati
on r
ep
orte
d i
n th
is
in
sta
lla
tio
n m
an
u
al
a
re s
u
sc
ep
tib
le to
c
h
an
g
e at a
ny ti
m
e a
n
d w
ith
ou
t o
b
lig
ati
on
o
n C
A
M
E c
an
ce
lli
auto
m
ati
ci
s.p.a. to n
otify u
se
rs.
ENGLISH
Trimmer A.C.T. =
Automatic closing time. Adjusts the wait time of the gate in the open position, also known as “pause time”;
at the end of this time, a closing movement is automatically activated. The “pause time” can be adjusted from 1 second to 120
seconds.
Trimmer PAR.OP. =
Partial opening. Adjusts the opening time of the gate. By pressing the partial opening button on 2-3P, the gate
will open for a set time between 2 and 15 seconds.
The automatic closing time will change in the following manner with this function:
- dip-switch 1 to ON «activated automatic closure» the closing time is set by adjusting the A.C.T. trimmer after partial opening;
- dip-switch 1 to OFF «deactivated automatic closure», with A.C.T. trimmer set to the minimum setting, automatic closure counting
does not start after partial opening; con trimmer del A.C.T. set to the maximum setting, the closing time is fi xed at 8 seconds after
partial opening.
1 ON -
Automatic closing - The automatic closing timer is automatically activated at the end of the opening cycle. The preset,
adjustable automatic closing time is automatically interrupted by the activation of any safety system, and is deactivated
after a total stop command or in case of power failure;
2 ON - Radio function command and/or “
open-stop-close-stop” button (with radio-frequency card inserted).
2 OFF - Radio function command and/or “
open-close-inversion” button (with radio-frequency card inserted).
3 ON - Radio function command and/or “
only open” button (with radio-frequency card inserted).
4 ON - “
Maintained Action” operations - Operation of the gate by keeping the pushbutton pressed (buttons connected on 2-3P and
2-7). It exclude the radio transmitter operations.
5 ON - “
Pre-fl ashing during opening and closing” - After an opening or closing command, the fl ashing lamp connected to W-E1
fl ashes for 5 seconds before beginning the manoeuvre.
6 ON -
Obstacle detection - With the motor not running (gate closed, open or after a total stop command), this hinders any
movement if the safety devices (e.g. photoelectric cells) detect an obstacle.
7 OFF -
Re-opening during closure - If the photoelectric cells identify an obstacle while the bar is closing, they will reverse the
direction of movement until the gate is completely open; insert safety device on the clamp (2-C1); if not used, select the dip
in ON.
8 OFF -
Partial stop - The gate stops if in motion with resulting order of automatic closing, insert safety device on the clamp (2-C3);
if not used, set the dip to ON.
9 OFF -
Total stop - This function stops the gate, with the resulting exclusion of an automatic closing cycle; to resume movement,
the pushbuttons or transmitters must be used. Insert the safety device on (1-2); if not used, set the dip to ON.
10 - If unused, leave the dip-switch in the “OFF” position.
6.7 Adjustments
6.6 Function selections