ENGLISH

Foreword

• This product should only be used for the purpose for which it was 
explicitly designed. Any other use is considered dangerous. CAME Cancelli 
Automatici S.p.A. is not liable for any damage resulting from improper, 
wrongful or unreasonable use • Keep these warnings with the installation 
and use manuals issued with the automation system.

Before installing

(preliminary check: in case of a negative outcome, do not proceed until you 
have complied with the safety requirements)

• Check that the part you intend to automate is in good mechanical 
condition, balanced and aligned, and that it opens and closes properly. 
Make sure that proper mechanical stops are already in place • If the 
operator will be installed at a height of less than 2.5 m from the ground 
or other access level, check whether you will need any protections and/
or warnings • Any leaves fi tted with pedestrian entrances onto which you 
will install an operator must have a blocking mechanism when the leaf is 
in motion • Make sure that the opening of the automated leaf is not an 
entrapment hazard as regards any surrounding fi xed parts • Do not mount 
the operator upside down or onto any elements that may fold under its 
weight. If needed, add suitable reinforcements at the points where it is 
secured • Do not install onto leaves not on level ground • Check that any 
lawn watering devices will not wet the operator from the bottom up.

Installation

• Carefully section off  the entire site to prevent unauthorised access, 
especially by minors and children • Be careful when handling operators 
that weigh more than 20 kg. In case, procure the tools required for safe 
gate movement • All opening commands (buttons, key selectors, magnetic 
readers etc.) must be installed at least 1.85 m from the perimeter of the 
area of turnstile movement, or where they cannot be reached from outside 
through the turnstile. In addition, direct controls (button, touch sensitive 
keys, etc.) must be installed at a height of at least 1.5 m and must not 
be accessible to the public • All ‘hold-to-run’ commands must be placed 
where the moving gate leaves, transit areas and driveways are completely 
visible • If missing, apply a permanent label that shows the position of the 
release mechanism • Before delivering to the user, check that the system 
is EN 12453 (impact test) standard compliant. Make sure that the operator 
has been properly adjusted and that the safety and protection devices as 
well as the manual release are working properly • Where necessary and in 
plain sight, apply the Warning Signs (e.g. gate plate)

Special instructions and advice for users

• Keep the gate’s area of operation clean and clear of any obstacles. Check 
that there is no vegetation in the area of operation of the photocells and 
that there are no obstacles in the area of operation of the operator • Do 
not allow children to play with the fi xed command devices, or in the gate’s 
area of operation. Keep any remote control devices (i.e. transmitters) or any 
control devices away from children as well, to prevent the operator from 
being activated accidentally •The operator is not designed to be used by 
persons (including children) whose physical, sensorial or mental capacities 
are limited, or who are lacking in experience or knowledge, unless said 
persons can be supervised or given instructions regarding using the 
operator by a person responsible for their safety • Frequently check the 
system, to see whether any anomalies or signs of wear and tear appear 
on the moving parts, on the component parts, on the securing points, on 
the cables and any accessible connections. Keep any joints (i.e. hinges) 
lubricated and clean, and do the same where friction may occur (i.e. slide 
rails) • Perform functional tests on photocells and sensitive edges every 
six months. To check that the photocells work, pass an object in front of 
them during closing. If the operator reverses the direction of movement or 
comes to a halt, the photocells work correctly. This is the only maintenance 
operation that must be carried out while the operator is live. Ensure that the 
glass on the photocells is kept clean (use a cloth slightly moistened with 
water; do not use solvents or any other chemicals as these could damage 
the devices) • If the system requires repairs or modifi cations, release the 
operator and do not use it until safety conditions have been restored • Cut 

off  the power supply before releasing the operator for manual openings 
and before any other operation, to prevent dangerous situations. Read the 
instructions • If the power cable is damaged, it must be replaced by the 
manufacturer or the technical assistance service or by a person with a 
similar qualifi cation so as to prevent any risks • It is STRICTLY FORBIDDEN 
for users to perform OPERATIONS THEY ARE NOT EXPLICITLY REQUIRED 
AND ASKED to do in the manuals. For repairs, adjustments and extraordinary 
maintenance, CONTACT THE SPECIALIST TECHNICAL SERVICE CENTRE • 
On the periodic maintenance log, note down the checks you have done. 

Special instructions and advice for all

• Avoid working near the hinges or moving mechanical parts • Stay clear 
of the gate’s area of operation when in motion • Do not resist the direction 
of movement of the gate; this may present a safety hazard • At all times 
be extremely careful about dangerous points that must be indicated by 
proper pictograms and/or black and yellow stripes • When using a selector 
or command in ‘hold-to-run’ mode, keep checking that there are no people 
in the area of operation of the moving parts. Do this until you release the 
command • The gate may move at any time without warning • Always cut 
the power when cleaning or performing maintenance. 

Danger of hand crushing

Danger - live parts

No transit during the manoeuvre

CAUTION!

important personal safety instructions:

READ CAREFULLY!

Danger of crushing feet

Summary of Contents for BX-P

Page 1: ...INSTALLATION MANUAL BX P AUTOMATION FOR SLIDING GATES English EN 119BT85EN ...

Page 2: ...e is no vegetation in the area of operation of the photocells and that there are no obstacles in the area of operation of the operator Do not allow children to play with the fixed command devices or in the gate s area of operation Keep any remote control devices i e transmitters or any control devices away from children as well to prevent the operator from being activated accidentally The operator ...

Page 3: ...30 x 8 module 4 rack with fastening screws holes and supports 009 CCT Simple 1 2 chain 009 CGIU 1 2 chain joint Important Check that the safety equipment and accessories are CAME originals this is a guarantee that also makes the system easy to set up and upkeep 4 Description 2 1 Destination 1 Legend This symbol indicates sections to be read with particular care This symbol indicates sections conce...

Page 4: ...any irregularities that may obstruct the gate s movement The upper guide rails must not create any friction Make sure that there is a closing and an opening endstops Make sure that the operator is attached to a solid surface and protected from any impacts Make sure you have a suitable omnipolar cut off device with contacts more than 3 mm apart and independent sectioned off power supply Check that ...

Page 5: ...al loads the sizes given on the table must be re evaluated based on actual power draw and distances When connecting products that are not specified in this manual please follow the documentation provided with said products 5 3 Cable list and minimum thickness Connection Type of cable Length of cable 1 10 m Length of cable 10 20 m Length of cable 20 30 m Control panel power supply 230V FROR CEI 20 ...

Page 6: ...xamples as the space for installing the ratiomotor and accessories varies according to obstructions It is thus up to the system installer to select the most suitable solution Shunt pit 5 5 Securing the plate and installing the assembly Conduits for electric cables Prepare the securing plate insert the bolts into the holes and lock them using the supplied nuts and washers Extract the preformed brac...

Page 7: ...NGLISH To position the plate in relation to the rack please see the measurements on the diagram Fill the form box with cement and wait for at least 24 hours for it to solidify Remove the form box fill the pit around the cement block with soil Unbolt the nuts and washers from the bolts The securing plate must be clean perfectly aligned and with the bolt threads completely on the surface Insert the e...

Page 8: ...e cable shafts Lift the gearmotor from the securing plate by about 5 to 10mm by using the threaded steel levelling feet to allow any later adjustments between the pinion and the rack The following illustrations for the securing the rack are just examples of applications It is up to the installer to choose the best solution Releasing the gearmotor see paragraph on manual release Rest the rack on th...

Page 9: ...e finished secure the assembly using the nuts and washers Insert the cover after performing the adjustments and settings on the electronic card Levelling feet Slotted holes Rack Pinion vertical adjusting horizontal adjusting Rack Pinion Open and close the gate manually and register the pinion to rack distance using the threaded steel levelling feet for vertical adjusting and the slotted holes horiz...

Page 10: ...obed key into the lock push it in and turn it clockwise 5 6 Mounting the endstop fins Place the endstop fins onto the rack and secure them using a 3 mm Allen wrench Their positioning limits the gate run Note the gate schould not slam against the mechanical stop when opening or closing Mechanical stop Trilobed key Knob open the small door and turn the release handle clockwise WARNING opening the doo...

Page 11: ...ts The card provides and controls the following optional functions automatic closing after an opening command pre flashing of the movement indicator obstacle detection with gate stopped at any point constant check of photocell operation The definable command modes are opening closing maintained action opening closing partial opening reopening during closing phase partial stop total stop The apposite...

Page 12: ...funzioni 5 Radiofrequency board coupling for remote control 6 Trimmer A C T automatic closing time adjustment 7 Trimmer PAR OP partial aperture adjustment 8 Save button of the radio codes of the remote control 9 LED signalling the radio code of the remote control 10 Terminal board for battery charge connection 11 Coupling radio frequency board for the pratico system 12 1 6A battery fuse 13 315mA c...

Page 13: ...e leaf by pressing the button or turning the key on the selector the gate leaf inverts its direction of motion or stops depending on the chosen selection made on the dip switches see selecting functions dips 2 and 3 Movement flashing light Contact output 230V 25W max Flashes during the gate s opening and closing phases Connections to warning and illumination devices Cycle lamp contact rating 230V 6...

Page 14: ...ENGLISH 6 3 Electrical connections Connection for gear motor limit switch or encoder Output for 230V AC motor connection RED ORANGE WHITE Eyelet cable terminal with screw and washer for ground connection Connections for power source and accessories Electric power 120V 230W AC 50 60 Hz 24V AC output to power accessories 20W max Condenser Possible output of the radio receiver s second channel N O so...

Page 15: ...vices partial stop N C contact Input for EN 12978 standard compliant safety devices such as photocells Gate stops if moving and automatically shuts if this functions has been selected N C contact for re open during closing phase Input for EN 12978 standard compliant safety devices such as photocells If contact is opened while gate is closing the gate inverts its direction Open while closing N C co...

Page 16: ... s p a to notify users ENGLISH 6 5 Motor torque limiter To change the torque move the faston identified by the black wire connected to the CT terminal to one of four positions 1 min 4 max 6 4 Gearmotor end stop connection Gearmotor end stop assembly already connected for installation on the left hand side seen from inside For right hand installation reverse FA FC of the end stops on the terminal bo...

Page 17: ...unting does not start after partial opening con trimmer del A C T set to the maximum setting the closing time is fixed at 8 seconds after partial opening 1 ON Automatic closing The automatic closing timer is automatically activated at the end of the opening cycle The preset adjustable automatic closing time is automatically interrupted by the activation of any safety system and is deactivated after...

Page 18: ...ation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH 7 Activating the radio control Possible output of the radio receiver s second channel NO contact Contact rated for 5A 24V DC Connect the antenna s RG58 cable Cut off the main power supply and remove any batteries Fit the AF board onto the electronic board The electron...

Page 19: ... to be changed repeat the sequence described above Insert the terminal connected to the battery to the free coupling of the motherboard The board must be battery powered for saving procedures Check the LED signalling 230V power is off Electric lock 8 Installation procedure for automatically releasing the motor pratico system The pratico system automatically releases the automation through the radi...

Page 20: ...roneous or negligent uses Avoid working close to the hinges or other moving mechanical parts Stay out of the opening closing arc when operator is in motion Do not exercise force against the motion of the operator as this could result in potentially dangerous situations Do not allow children to play or loiter within the opening closing arc of the operator Keep remote controls and any other command ...

Page 21: ...ble accidents due to gate movement To clean the photocells use a water dampened cloth Do not use solvents or other chemical products which may ruin the devices In the event of any strange vibrations or squeaking lubricate the joints with grease as shown in the diagram Make sure there are no plants within the photocell s beam and that the gate motion is free of any obstacles 10 2 Trouble shooting M...

Page 22: ...__________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ Installer s stamp Operator name Date of job Technician s signature Requester s signature Job performed _______________________________________________________________________________________ ...

Page 23: ...ed at authorised firms Other components electrical circuit board remote control batteries etc may contain hazardous waste They must thus be removed and turned in to licensed firms for their disposal Before acting always check the local laws on the matter DO NOT DISPOSE OF IN NATURE 11 Phasing out and disposal 12 Conformity declaration Installer s stamp Operator name Date of job Technician s signat...

Page 24: ...e over het bedrijf de producten en hulp in uw eigen taal PT Para toda e qualquer informação acerca da empresa de produtos e assistência técnica em sua língua PL Wszystkie inne informacje dotyczące firmy produktów oraz usług i pomocy technicznej w Waszym języku znajdują się na stronie RU Для получения дополнительной информации о компании продукции и сервисной поддержке на вашем языке HU A vállalatra...