Encoder
Manage operator slowdowns, obstacle detection and sensitivity.
F11
OFF
ON (Default)
Soft start
Set a slowdown of a few seconds after each opening and closing command.
F12
OFF (Default)
ON
Sensor type
Set the type of control device.
F14
0 = Transponder selector switch
1 = Keypad selector (default)
Additional light
Choose the operating mode of the lighting device connected to the output.
F18
0 =Flashing beacon (Default)
1 = Cycle light.
The light remains off if an automatic closing time is not set.
Automatic closure
Set the time before automatic closure is activated, once the opening travel end point has been reached.
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a complete stop, during a power outage or if there is an
error.
F19
OFF (Default)
From 1 to 180 seconds
Automatic closing after partial opening
Set the time before automatic closure is activated, after a partial opening command has been performed.
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a complete stop, during a power outage or if there is an
error.
Do not deactivate the function [Automatic close].
F20
OFF
1 to 180 seconds (Default 10 seconds)
Pre-flashing time
Set the time for which the beacon is activated before each manoeuvre.
F21
OFF (Default)
1 to 10 seconds
Gate travel speed
Set the travel speed (percentage of maximum speed).
F28
50% to 100% (Default 100%)