ERROR AND WARNING MESSAGES
E1
The travel calibration was interrupted to activate the STOP button.
E2
Adjustment error
E3
Motor control error
E4
Service test failure error
E7
Operating time error
E9
Obstacle detected during closing
E10
Obstacle detected during opening
E11
The maximum number of obstacles detected consecutively has been exceeded
E13
The limit switches are both open
E14
Serial communication error
E15
Incompatible transmitter error
E17
Wireless system communication error
E18
Wireless system not configured error
C0
Wire contact 1-2 (NC) is open.
C1, C2, C3, C4
The photocell wire contact (NC) is open.
C7, C8
The sensitive edge wire contact (NC) is open.
P0
The wireless radio contact 1-2 (NC) is open.
P1, P2, P3, P4
The photocell wireless radio contact (NC) is open.
---
Control board has no travel auto-learning
Troubleshooting
Error shown
Action
E3
Connect cables MN and +E-
Check the gate is not blocked
The encoder module is not installed
Measure the voltage between M and N
Thermal protection is activated
Check the position of the limit-switches and speed (gate open and gate closing)
Check the control board is intact