background image

INSTALLATION MANUAL

F40230E - F4024E - F4024EP

GEARMOTOR 

FOR SWING OR FOLDING DOORS

FA 0 0 0 3 4 - E N

English

EN

Summary of Contents for F40230E

Page 1: ...INSTALLATION MANUAL F40230E F4024E F4024EP GEARMOTOR FOR SWING OR FOLDING DOORS FA00034 EN English EN ...

Page 2: ...ations Keep gate operation areas clean and free of any obstructions Make sure that the photocells are free of any overgrown vegetation and that the operator s area of operation is free of any obstructions Do not allow children to play with fixed commands or to loiter in the gate s maneuvering area Keep any remote control transmitters or any other command device away from children to prevent the ope...

Page 3: ...0 1 2 200 Technical data Type F40230E F4024E F4024EP Protection rating IP 54 54 54 Power supply V 50 60 Hz 230 AC 230 AC 230 AC Motor power supply V 230 AC 50 60 Hz 24 DC 24 DC Power draw A 1 2 Max 5 Max 10 Power W 235 130 180 Torque Nm 340 360 470 Crown revolutions rpm 1 3 1 3 2 4 Gear ratio i 1 150 1 150 1 150 Condenser μF 16 Duty cycle 30 INTENSIVE USE INTENSIVE USE Operating temperature C 20 5...

Page 4: ...0 34 E N ver 2 2 08 2015 Came S p A The contents of this manual may be revised at any time and without notice 1 Gearmotor 2 Cap with hole 3 Cap 4 UNI 5931 M8x120 screw 5 UNI 5588 M8 nut 6 Spring 7 Release handle 8 Endstop device Description of the components Dimensions mm ...

Page 5: ...N ver 2 2 08 2015 Came S p A The contents of this manual may be revised at any time and without notice 1 Gearmotor 2 Transmission arm with slide guide 3 Control panel with radio receiver 4 Flashing light with antenna 5 Photocells 6 Gearmotor release 7 Photocell post Example of a system ...

Page 6: ...n If the distance between the slide guide A and the door leaf is insufficient for installing the gearmotor then fit it as shown in the figure while respecting the quotas shown One Door with two leaves Folding leaf consisting of two hinged panels The gearmotor is fitted onto panel A Single swing leaf One Door with two leaves Folding leaf consisting of two hinged panels The gearmotor is fitted onto ...

Page 7: ...need for the installation at hand to work in total safety and compliance with current standards and regulations The figure shows some examples of installer s tools Types of cables and minimum thicknesses Connection Cable type Cable length 1 10 m Cable length 10 20 m Cable length 20 30 m Power supply to board 230 VAC FROR CEI 20 22 IEC EN 50267 2 1 3G x 1 5 mm2 3G x 2 5 mm2 3G x 4 mm2 Power supply ...

Page 8: ... examples Consider that the space available where to fit the operator and accessories will vary depending on the overall measurements The installation technician is responsible for choosing the most suitable solution Setting up corrugated tubing Set up the corrugated Ø 25 mm tubing you will need to connect the junction boxes The number of tubes depends on the type of system and accessories you wil...

Page 9: ... 0 0 0 34 E N FA 0 0 0 34 E N ver 2 2 08 2015 Came S p A The contents of this manual may be revised at any time and without notice Anchoring the base and the slide guide Caution Respect the quotas shown in the drawing APPLICATION ON DOUBLE LEAF DOOR APPLICATION ON SINGLE LEAF DOOR ...

Page 10: ... F F4 F W V U Pag 10 10 Manual code FA 0 0 0 34 E N FA 0 0 0 34 E N ver 2 2 08 2015 Came S p A The contents of this manual may be revised at any time and without notice Fixing the transmission arm APPLICATION ON FOLDING DOOR APPLICATION ON SWING LEAF DOOR Releasing the gearmotor ...

Page 11: ...manual may be revised at any time and without notice APPLICATION ON DOUBLE LEAF DOOR APPLICATION ON SINGLE LEAF DOOR Securing the gearmotor Fit the arm into the guide and the gearmotor onto the base plate Fasten the gearmotor using the two M8 x 110 bolts and their M8 nuts supplied Fit the hole caps and guide caps N B Use suitable cable glands for threading the cables and the release cable ...

Page 12: ...without notice Warning If no mechanical door stops are in place you must adjust the endstops Determining the end run points Fit the cams onto the guide During closing fully close the door leaf turn the cam clockwise until the closing microswitch activates fasten the cam using the screw Closing microswitch Cams Cam guide Closing microswitch ...

Page 13: ... Came S p A The contents of this manual may be revised at any time and without notice Opening microswitch During opening fully open the door leaf turn the cam counter clockwise until the opening microswitch is activated fasten the cam using the screw Opening microswitch ...

Page 14: ... 14 Manual code FA 0 0 0 34 E N FA 0 0 0 34 E N ver 2 2 08 2015 Came S p A The contents of this manual may be revised at any time and without notice ELECTRICAL CONNECTIONS Delayed opening action gearmotor Delayed closing action gearmotor ...

Page 15: ...ag 15 15 Manual code FA 0 0 0 34 E N FA 0 0 0 34 E N ver 2 2 08 2015 Came S p A The contents of this manual may be revised at any time and without notice Delayed opening action gearmotor Delayed closing action gearmotor ZLJ24 control panel for doors with two leaves ZLJ14 control panel for doors with one leaf ...

Page 16: ...l code FA 0 0 0 34 E N FA 0 0 0 34 E N ver 2 2 08 2015 Came S p A The contents of this manual may be revised at any time and without notice Fit the frame cover FINAL OPERATIONS Fasten the cover and the release handle Ø 13 5 mm UNI 6954 Ø 3 9x13 washer and screw ...

Page 17: ...SHOOTING PROBLEMS POSSIBLE CAUSES CHECKS AND REMEDIES The door does not open or close No power The gearmotor is unlocked The transmitter battery is flat The transmitter is broken The stop button is stuck or broken The open close button or selector switch are stuck Check for mains power Lock the gearmotor Replace the batteries Contact service Contact service Contact service The door opens but will ...

Page 18: ... to note any extraordinary maintenance repairs or improvements carried out by specialist companies N B Extraordinary maintenance must be carried out by specialist technicians Extraordinary maintenance log MAINTENANCE Periodic maintenance Before doing any maintenance cut off the power supply to prevent any hazardous situations caused by accidentally activating operator Periodic maintenance log kept...

Page 19: ...ore proceeding it is always advisable to check specific regulations in force in the place of installation DISPOSE OF PROPERLY DISPOSAL OF THE PRODUCT Our products are made with different materials Most of them aluminium plastic iron electrical cables can be disposed of together with normal household waste They can be recycled if collected sorted and sent to authorised centres Other components circ...

Page 20: ...n di Casier Treviso Treviso Italy 33079 Sesto al Reghena Sesto al Reghena Pordenone Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 Manual code FA 0 0 0 34 E N FA 0 0 0 34 E N ver 2 2 08 2015 Came S p A The contents of this manual may be revised at any time and without notice ...