GENERAL PRECAUTIONS FOR INSTALLERS
Important safety instructions.
Follow all of these instructions. Improper installation can cause serious bodily harm.
Before continuing, also read the general precautions for users.
Use this product only for its specifically intended use. Any other use is hazardous. • The manufacturer can not be held
liable for any damage caused by improper, unreasonable, and erroneous use. • This manual's product is defined by the
Machinery Directive 2006/42/CE as partly-completed machinery. • Partly-completed machinery is an assembly that
almost constitutes a machine, but which, alone, cannot ensure a clearly defined application. • Partly-completed machinery
is only destined to be incorporated or assembled to other machinery or other partly-completed machinery or apparatuses
to build machinery that is regulated by the Machinery Directive 2006/42/EC. • The final installation must comply with
the Machinery Directive 2006/42/EC and the current European reference standards. • The manufacturer declines any
liability for using non-original products; which would result in warranty loss. • All operations indicated in this manual must
be carried out exclusively by skilled and qualified personnel and in full compliance with current regulations. • Laying of
cables, installation and testing must follow state-of-the-art procedures as dictated by applicable standards and laws. • All
the components (e.g. control panels, photocells, sensitive edges, etc.) necessary for the conformity of the final installation
in accordance with the Machinery Directive 2006/42/EC and with the reference harmonized technical standards are
identified in the CAME products general catalog or in the website www.came.com. • Make sure the mains power supply
is disconnected during all installation procedures. • Check that the temperature ranges given and those of the location
match. • If necessary, add suitable reinforcements to the anchoring points. If necessary, add suitable reinforcements
to the anchoring points. • Make sure that the operator, in the installation place, does not get wet by direct jets of water
(sprinklers, water cleaners, etc.). • Make sure you have set up a suitable dual pole cut off device along the power
supply that is compliant with the installation rules. It should completely cut off the power supply according to category III
surcharge conditions. • Demarcate properly the entire site to prevent unauthorized personnel to enter; especially children
and minors. • In case of manual handling, have one person for every 20 kg that need hoisting; for non manual handling
use proper hoisting equipment in safe conditions. • Use suitable protections to prevent any mechanical hazards due to
persons loitering within the operating range of the operator. • The electric cables must pass through special pipes, ducts
and cable glands in order to guarantee adequate protection against mechanical damage. • The electrical cables must not
touch any parts that may overheat during use (such as the motor and the transformer). • Before the installation, check that
the guided part is in good mechanical condition, and that it opens and closes correctly. • The product cannot automate
any guided part that includes a pedestrian gate, unless the latter can be enabled only when the pedestrian gate is secured.
• Make sure that people cannot be entrapped between the guided and fixed parts, when the guided part is set in motion.
• All fixed controls must be clearly visible after installation, in position that the guided part is directly visible, but far away
from moving parts. In the case of a maintained action command, this must be installed at a minimum height of 1.5 m from
the ground and must not be accessible to the public. • If not already present, apply a permanent tag, that describes how
to use the manual release mechanism, close to the mechanism. • Make sure that the operator has been properly adjusted
and that the safety and protection devices, and the manual release, are working properly. • Before turning over to the final
user, check that the system complies with the harmonized standards and the essential requisites of Machinery Directive
2006/42/CE. • Any residual risks must be indicated clearly with proper signage affixed in visible areas. All of which must
be explained to end users. • Fit, in plain sight, the machine's ID plate when the installation is complete. • If the power-
supply cable is damaged, it must be immediately replaced by the manufacturer or by an authorized technical assistance
center, or in any case, by qualified staff, to prevent any risk. • Keep this manual inside the technical folder along with
the manuals of all the other devices used for your automation system. • Remember to hand over to the end users all the
operating manuals of the products that make up the final machinery.
Summary of Contents for FA70230CB
Page 2: ...1 2 3 5 6 4 ...
Page 29: ...Swing gate operator FA70230CB INSTALLATION MANUAL FA01335 EN EN English ...
Page 30: ...1 2 3 5 6 4 ...
Page 57: ...Automatismes pour portails battants FA70230CB MANUEL D INSTALLATION FA01335 FR FR Français ...
Page 58: ...1 2 3 5 6 4 ...
Page 85: ...Автоматика для распашных ворот FA70230CB РУКОВОДСТВО ПО МОНТАЖУ FA01335 RU RU Русский ...
Page 86: ...1 2 3 5 6 4 ...