17
5.2 - Opening & Closing the Gates
1.
Momentarily pulse terminals
2 & 7 with a piece of wire trailing
from terminal 2 and momentarily
touching terminal 7.
The gates should start to open.
If they start to close turn the
power off to the control panel
and change around either U-V
(motor 1) or X-Y (motor 2) to
change the motor direction.
2.
Once you have proven the
motor direction use terminals
2 & 7 to open and close the
gates with a trailing wire once
again into terminal 2,
momentarily touching
terminal 7.
W X Y E
L1 L2
7 2
C1
11 10
ES
5
ES
1
W X Y E
L1 L2
7 2
C1
11 10
ES
5
ES
1