FA00150-EN v.7 - 06/2017
18
CAME S.p.A.
10. INSTALLATION SIGNALING DEVICE DOOR POSITION 001FLA-06
- Secure the bracket with magnet on the carriage at the location of the
opening or closing of the door.
- Attach by front hooking, the magnetic microswitch on the drive unit
profile, bring the door in opening or closing position, and place it in
correspondence of the bracket with the magnet fixed on the carriage.
- Adjust the distance between the magnetic microswitch and the
magnet so as to obtain the proper activation of the microswitch.
- Connect the microswitch to signal processing devices, not supplied by
us, such as: interlock devices, alarm system, etc.
The color of the wires has the following meaning: white = common;
black = N.O.; blue = N.C.
11. INSTALLATION SIGNALING DEVICE LOCK POSITION 001FLA-04
The microswitch can be fixed to either the locking device (001FLA-03)
and both the unlocking device (001FLA-05), using the screws provided.
11.1 Connecting the microswitch on locking device (001FLA-03) in
automation for emergency exits (EMERGENCY).
Connect the microswitch to terminals of the electronic control, using
the included cable (common = 1; N.O. = S1).
11.2 Connecting the microswitch on unlocking device (001FLA-05)
to
open the door
.
Connect the microswitch to terminals of the electronic control, using
the included cable (common = 1; N.O. = KO).
11.3 Connecting the microswitch on locking device (001FLA-03) to
signal processing devices, not supplied by us, such as: interlock device,
alarm system, etc.
Note: to make sure that the door is closed and locked, connect to the
signalling device in combination to the signalling device door position
[001FLA-06].