FA00150-EN v.7 - 06/2017
28
CAME S.p.A.
13 ELECTRONIC CONTROL ADJUSTEMENT
The electronic control has 4 buttons and 4 alphanumeric displays to set all the necessary adjustments.
After turning on the electronic control, the display shows the word "MENU". The operation of the four keys are indicated in
the table.
Keys
Description
ENTER
Select button, each time you press the button you enter on the
selected parameter.
Save button, pressing for 1 seconds you "SAVE" the selected value.
There are the following menu:
MENU = Main parameters menu
MEM = Memory management menu
ADV = Advanced parameters menu
SEL = Function selector menu
INFO = Information and diagnostics menu
ESC
Exit button, exit from all the parameter or exit from the menu.
↑
Scroll button, each press selects a menu item or increases the value
of the selected item.
↓
Scroll button, each press selects a menu item or reduces the value of
the selected item.
13.1 MAIN SETTINGS MENU
Using the buttons ↑ and ↓ choose MENU, press ENTER to select and adjust the following main parameters:
Display
Description
Factory settings
DOOR
DDOR TYPE
Setting the automation type. Choose from the following values:
SL5A = automation for standard doors
SL5B = automation BIG version, for very heavy doors
SL5A
OPEN
OPENING
DIRECTION
Setting the opening direction. Choose between the following values:
↔ → = 2-leaves door or 1-leaf door opening to right;
← = 1-leaf door opening to left.
EMERGENCY
- In the case of 1-leaf Emergency automation with opening on the left, the carriage must
be fixed to the belt at the top, as indicated in chapter 15.1.
↔ →
PART
PARTIAL
OPENING
Setting the percentage of partial opening. Choose between the minimum and maximum:
minimum value = 10%
maximum value = 90%
EMERGENCY
- In case of Emergency automation, the partial opening must meet the local legal
requirements.
90
VOP
OPENING
SPEED
Opening speed setting. Choose between the minimum and maximum:
minimum value = 100 mm/s
maximum value = 800 mm/s
EMERGENCY
- In case of Emergency automation, set the opening speed ≥ 300 (if 2-leaves door), or ≥
550 (if 1-leaf door).
If the door is Heavy model or Big model (DOOR = SL5B), the set speed is automatically reduced to
allowed values (see the technical data).
500
VCL
CLOSING
SPEED
Closing speed setting. Choose between the minimum and maximum:
minimum value = 100 mm/s
maximum value = 800 mm/s
If the door is Heavy model (DOOR = SL5H) or Big model (DOOR = SL5B), the set speed is automatically
reduced to allowed values (see the technical data).
300
TAC
CLOSING
TIME
Open door time setting. Choose between the minimum and maximum:
NO = the door is always open
minimum value = 1 s
maximum value = 30 s
1
PUSH
MOTOR
POWER
Force setting. Choose between the minimum and maximum:
minimum value = 1
maximum value = 10
10