Display
Description
Factory settings
STG1
G1-SETTING
Operation of the G1 terminal. Choose between the following values:
NO = no function
STOP = Stop contact N.C. The opening of the 1-G1 contact stops the door.
EMERGENCY
- Setting not available for Emergency automation.
STEP = Step-by-step contact N.O. The closing of the 1-G1 contact performs in sequence the opening
(disabled automatic closure) and the closing of the door.
SAM = Automatic setting command of function selector. The closing and the opening of the 1-G1
contact changes the function selector mode (see menu settings: SEL > SAM1 and SEL > SAM2).
EMER = Emergency opening contact N.C. The opening of the 1-G1 contact opens the door.
PART = Partial opening contact N.O. (see menu: MENU > PART > 10-90).
CAB = Step-by-step contact N.O. The closing of the 1-G1 contact performs in sequence the closing of
the door (disabling 3A/3B terminals, enabling the signaling for occupied cabin) and the opening of the
door (enabling 3A/3B terminals, disabling the signaling for occupied cabin).
NO
STG2
G2-SETTING
Operation of the G2 terminal. Choose between the following values:
NO = no function
STOP = Stop contact N.C. The opening of the 1-G2 contact stops the door.
EMERGENCY
- Setting not available for Emergency automation.
STEP = Step-by-step contact N.O. The closing of the 1-G2 contact performs in sequence the opening
(disabled automatic closure) and the closing of the door.
SAM = Automatic setting command of function selector. The closing and the opening of the 1-G2
contact changes the function selector mode (see menu: SEL > SAM1 and SEL > SAM2).
EMER = Emergency opening contact N.C. The opening of the 1-G2 contact opens the door.
PART = Partial opening contact N.O. (see menu: MENU > PART > 10-90).
CAB = Step-by-step contact N.O. The closing of the 1-G2 contact performs in sequence the closing of
the door (disabling 3A/3B terminals, enabling the signaling for occupied cabin) and the opening of the
door (enabling 3A/3B terminals, disabling the signaling for occupied cabin).
BELL = Output 0-G2 (12Vdc 20mA). The output is activated for 3 seconds when people enter the store
(through the sequential activation of the safety contacts: 1-8B and 1-8A).
SIGN = Output 0-G2 (12Vdc 20mA). The output is activated when the door is in the closed or opening
position (see menu: ADV > SIGN).
SERV = Output 0-G2 (12Vdc 20mA). The output is activated when the door reaches the number of
maintenance cycles, set using the menu: INFO> SERV.
WARN = Output 0-G2 (12Vdc 20mA). The output is activated when at least one warning remains
active for 5 minutes. For remove the alarm signal make a reset or turn off the power supply.
NO
SIGN
DOOR
POSITION
SIGNAL
Door position indication through the 0-G2 output (see menu: ADV > STG2 > SIGN). Choose between
the following values:
CLOS = closed door
OPEN = open door
LOCK = closed and locked door
AIR = door not closed
LAMP = moving door
CAB =
signaling of the occupied cabin
(see menu: ADV > STG1 > CAB)
CLOS
T41
SAFETY TEST
Enable test for safety devices (in accordance with EN 16005). Choose between the following values:
NO = test disabled
YES = test enable
YES