FA00150-EN v.7 - 06/2017
38
CAME S.p.A.
16. TROUBLESHOOTING
In addition to the following list of possible problems, there are warnings provided by the display, as described in chapter
13.5.
Problem
Possible causes
Remedy
The automation does not
open or close.
No power supply (display off).
Check the power supply.
Blow line fuse (display off).
Replace the mains fuse.
Short circuited external accessories.
Disconnect all accessories from terminals 0-1
and reconnect them one at a time (check for
voltage 12V).
The door is locked by bolts and locks.
Check the freely move of the doors
The automation does not
perform the functions set.
Function selector incorrectly set.
Check and correct the settings of the function
selector.
Control devices or safety always
activated.
Disconnect devices from the terminal and verify
the operation of the door.
The movement of the doors
isn’t linear, or reverse the
movement for no reason.
The automation does not successfully
perform the automatic learning.
Perform a reset using the command 1-29 , or
power off and power on the automation.
The automation opens but
does not close
Anomalies during the safety devices
test.
Jumper contacts one at a time 41 -8A , 41 -8B ,
41 - 6A, 6B - 41 .
The opening devices are activated.
Verify that the opening sensors are not subject
to vibration , do not perform false detections or
the presence of moving objects in the field of
action.
The automatic closing doesn’t work.
Check the settings of the function selector .
Safety devices not activating.
Incorrect connections between the
safety devices and electronic control.
Check that the safety contacts of the devices
are properly connected to the terminal blocks
and the relative jumpers have been removed.
The automation opens by
itself.
The opening and safety devices are
unstable or detect moving bodies
Verify that the opening sensors are not subject
to vibration , do not perform false detections or
the presence of moving bodies in the field of
action.
The
EMERGENCY
automation is testing
the emergency opening.
Wait for the test run..
The
EMERGENCY
automation has
detected a fault.
Check for the presence of the power supply.
Check the connection of the battery and its
efficiency.
Check the contact closure 1-EO.
Make sure that the function selector device is
in protected mode (the padlock symbol should
be lit).
If present, check the position of the locking
device and the connection 1-S1.
The locking device doesn’t
lock or unlock the doors.
Wrong connection of the locking device
to the electronic control.
Check the correct color connection of the
locking device
The attachment lock brackets, fixed on
carriage, will not release
Check the adjustment of the position of the
brackets coupling lock.
Pulling the release cord don’t unlock the
doors.
Check the correct fitting of the release cord on
the lock.