F5 Safety
test
0 = Deactivated (
default
) / 1 = CX / 2 = CY / 3 = CX+CY
After every opening or closing command, the board will check whether the photocells are working properly.
F6 Hold-to-run
0 = Deactivated (
default
) / 1 = Activated
Press and hold a button to open and close the barrier. Opening button on [2-3]; closing button on contact [2-4]. With this function active, all
other command devices, including radio, are excluded.
F9
Obstruction detection function with motor idle
0 = Deactivated (
default
) / 1 = Activated
With the barrier open or closed or after a total stop, if the safety devices (photocells or safety edges) detect an obstacle the operator remains
stationary.
F10 Indicator
light
0 = on with boom raised and moving (
default
) /
1 = fl ashes intermittently every half second during opening
fl ashes intermittently every second during closing
on
with
boom
raised
off
with
boom
lowered
It signals the barrier status. The light is connected to [10-5].
F11 Exclude
encoder
0 = encoder activated (
default
) / 1 = encoder deactivated*
It manages slow-downs, obstruction detection and sensitivity.
* Connect the micro-switches to F-FC-FA.
F14
Sensor type selection
0 = control with transponder sensor or magnetic card reader
1 = control with keypad selector (
default
)
Setting the type of sensor to control the barrier.
F15
Luminous cord intermittence
0 = Boom moving (
default
) / 1 = Boom moving and closed
It signals the status of the barrier with intermittent lights.
F18 Additional
light
0 = Flashing light (
default
) / 1 = Beacon / 2 = Courtesy light
Output on [10-E1].
The fl ashing light functions during opening and closing.
The beacon stays on from the moment the barrier begins to open until it is fully closed (including automatic closing time). Where the
automatic closing function is not activated, it only stays on during barrier movement.
The courtesy light either stays on for a fi xed period of 180 seconds or can be adjusted; see function F 25.
F19
Automatic closing time
0 = Deactivated (
default
) / 1 = 1 s / 2 = 2 s / … / 180 = 180 s
The waiting time before the barrier closes automatically starts when the limit-switch point is reached during opening. The time can be set
to between 1 s and 180 s. The barrier is not closed automatically where the safety devices are triggered by an obstacle, after a total stop or
where there is no power.
F21 Pre-fl
ashing
time
0 = Deactivated (
default
) / 1 = 1 s / … / 5 = 5 s
After an opening or closing command is given, the fl ashing light connected to 10-E1 fl ashes for between 1 s and 10 s before the barrier
begins to move.
F22 Working
time
5 = 5 s / ...../ 120 = 120 s (
default
)
Gearmotor cycle time during opening or closing.
The working time can be set to between 5 s and 120 s
F25
Courtesy light time
5 = 5 s / ...../ 120 = 120 s (
default
).
Additional light; it stays on when the barrier opens and closes.
The time can be set to between 5 s and 120 s
F28
Opening manoeuvre speed
70 = Minimum speed / … / 100 = Maximum speed.
Setting the boom opening speed, calculated as a percentage.
⚠
Warning: the speed parameter fi elds vary according to the type of boom:
- for booms with a joint, between 2 m and 4 m, set the speed percentage from 70 to 100;
- for booms between 6 m and 8 m, set the speed percentage from 80 to 100.
F29
Closing manoeuvre speed
70 = Minimum speed / … / 100 = Maximum speed.
Setting the boom closing speed, calculated as a percentage.
⚠
Warning: the speed parameter fi elds vary according to the type of boom:
- for booms with a joint, between 2 m and 4 m, set the speed percentage from 70 to 100;
- for booms between 6 m and 8 m, set the speed percentage from 80 to 100.
Summary of Contents for G2080E
Page 33: ...Automatic barriers GARD 8 series G2080E G2080IE INSTALLATION AND OPERATION English FA01030 EN...
Page 65: ...Barri res automatiques s rie GARD 8 G2080E G2080IE MANUEL D INSTALLATION Fran ais FA01030 FR...
Page 97: ...GARD 8 G2080E G2080IE FA01030 RU...
Page 98: ...2 FA01030 RU 1 01 2018 CAME S p A CAME S P A 2 5 20 1 8 1 5 EN12453 EN12445 8...
Page 103: ...7 FA01030 RU 1 01 2018 CAME S p A 24 600...
Page 104: ...N M 8 FA01030 RU 1 01 2018 CAME S p A 90 M N...
Page 105: ...UNI5931 M8x20 UNI5931 M8x12 UNI5931 M8x20 UNI6954 2 9x13 9 FA01030 RU 1 01 2018 CAME S p A...
Page 107: ...11 FA01030 RU 1 01 2018 CAME S p A 45 UNI5739 M12x70 UNI5588 M12...
Page 113: ...1 8 9 1 8 9 17 FA01030 RU 1 01 2018 CAME S p A 89...
Page 121: ...10 11 1 E 10 11 1 E 4 Z L 3 8 25 FA01030 RU 1 01 2018 CAME S p A...
Page 125: ...29 FA01030 RU 1 01 2018 CAME S p A 6...
Page 127: ...31 FA01030 RU 1 01 2018 CAME S p A CAME S p A UNI EN ISO 14001...