11 Demolition and disposal

 In its premises, CAME CANCELLI AUTOMATICI S.p.A. implements an Environmental Management System certifi ed in com-

pliance with the UNI EN ISO 14001 standard to ensure environmental protection.
Please continue our eff orts to protect the environment—which CAME considers one of the cardinal elements in the development 
of its operational and market strategies—simply by observing brief recommendations as regards disposal:

 DISPOSAL OF PACKAGING – The packaging components (cardboard, plastic, etc.) are all classifi able as solid urban waste pro-

ducts and may be disposed of easily, keeping in mind recycling possibilities.
Prior to disposal, it is always advisable to check specifi c regulations in force in the place of installation.
PLEASE DISPOSE OF PROPERLY!

 PRODUCT DISPOSAL – Our products are made up of various types of materials. Most of them (aluminium, plastics, iron, electrical 

wires, etc.) may be disposed of in normal garbage collection bins and can be recycled by disposing of in specifi c recyclable material 
collection bins and disposal in authorized centres. Other components (electrical boards, remote control batteries, etc.), however, may 
contain polluting substances. They should therefore be removed and given to qualifi ed service companies for proper disposal.
Prior to disposal, it is always advisable to check specifi c regulations in force in the place of disposal.
PLEASE DISPOSE OF PROPERLY!

10.3 Problem solving

MALFUNCTIONS

REFERENCES

CHECKS

The unit neither opens nor shuts

1-2-3-4-6-8-18

1 – Close the inspection hatch with the key and check the 
release lock

The unit opens but does not close

4-7-10

2 - Disable “steady movement” with dipswitch

The unit shuts but does not open

4-7-9

3 – Check power supply and fuses

No automatic closure

11-12-13

4 - N.C. safety contacts open (1-2 / 2-C1 / 2-C5)

The unit does not work if the remote control is 
used

2-14-16

6 - Disable master-slave function

The unit inverts direction

7-18

7 – Check spring tension and balancing

The unit works only with remote control

22

8 – Disable obstacle detection with dipswitch

The photoelectric cell does not react

12-23-24

9 – Check if end stop opens

The signalling LED indicator flashes rapidly

4

10 – Check if end stop closes

The signalling LED indicator remains on

13

11 - Activate “automatic closure” dip switch

The unit does not end its run

7

12 – Check the correct direction of movement

The bar is not properly balanced

7-15

13 - (2-3 / 2-4 / 2-7) command button

The unit does not slow down

7-15

14 –Check jumper on AF43S, turn on/off power

The unit does not work with the back-up 
batteries

8-25-26

15 – Check the bar length ratio with mountable accessories

The unit is slow to respond

7

16 – Re-save radio code

18 – Adjust sensitivity

22 - Enter or duplicate the same code in all the remote 
controls

23 – Activate the photoelectric cell with the dipswitch

24 – Connect the photoelectric cells in a series, not in 
parallel

25 – Dead batteries

26 –Respect the photoelectric cells’ polarity 

Summary of Contents for G4000

Page 1: ...G4000 G4001 G4000N INSTALLATION MANUAL STREET BARRIER AUTOMATION English EN 119G25EN...

Page 2: ...pletely visible If missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system is EN 12453 impact test standard compliant M...

Page 3: ......

Page 4: ...Joint for the G0401 G0468 Support for applying DOC series photocells to cabinet G0469 Support for applying the ashing light to the cabinet LB38 Battery card for connecting 3 12V 7Ah batteries Importa...

Page 5: ...thick sheet metal cabinet with galvanised varnished finish G4000 RAL 2004 G4000N RAL rough grey or 2 mm thick satin polished stainless steel G4001 ready to fit all accessories Inspection door with cus...

Page 6: ...lation it is necessary to Make sure the area selected for the mounting of the base and for the unit itself presents no hazards Provide for suitable omnipolar disconnection device with more than 3 mm b...

Page 7: ...a in the table must be made based on the effective absorption of the connected devices according to the instructions indicated by the CEI EN 60204 1 standards For connections that require several load...

Page 8: ...ng clamps at the base Prepare a hole to house the fixing base and prepare sheath tubes from the branch pit for the connections N B the number of tubes depends on the type of system and the accessories...

Page 9: ...e right length and secure via the A boom supporting attachment using the four supplied bolts Check the horizontal and vertical positions by adjusting the B C internal travel stops 5 7 Balancing the bo...

Page 10: ...ngle 4 Now tighten the locknut and lock the gear motor M12 rh jointed rod M12 nut M12 lh eye rod Pull force WARNING Unlocking the barrier may be dangerous for users if the boom is wrongly secured duri...

Page 11: ...he bar stops during closing the bar reverses its direction until it opens completely automatic closure is thus activated Caution after three consecutive direction reversals the bar will remain up and...

Page 12: ...matici s p a to notify users ENGLISH Deceleration Speed Max Min Max Avg Min 1 Terminal boards for external connections 2 Line fuse 3 Accessories fuse 4 Select Function dip switch 5 Radiofrequency term...

Page 13: ...tomatici s p a to notify users ENGLISH 6 2 Electrical connections The swing joint in the picture which is factory made is for a left hand barrier see par 5 8 24V d c Motor Gearmotor endstop Closing mi...

Page 14: ...and or button connection N O contact Boom opening and closing command Pressing the button inverts movement of the boom Check position of Jumper n 12 page 10 as shown in the gure Opening button N O co...

Page 15: ...within the range of the safety devices If unused set Dipswitch 8 to ON DIR photocells DIR photocells Safety devices DOC photocells DOC photocells Contact N C for immediate closing If not used position...

Page 16: ...e inversion enabled with radiofrequency card slot 3 ON 24V voltage in output on terminals 10 E during movement cycles and when in the barrier closed position enabled 3 OFF 24V voltage in output on ter...

Page 17: ...e at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Lock the radiofrequency card into the electronic card AFTER CUTTING OFF THE POWER SUPPLY or after disconn...

Page 18: ...a to notify users ENGLISH Radio card PROG Keep pressed the PROG button on the electronic board The LED light will ash Press the button of the transmitter to be memorie The LED light will stay lit to s...

Page 19: ...automatici s p a The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH De...

Page 20: ...by accident In the event of anomalous behaviour stop using the operator immediately Danger of crushing hands Danger High voltage No transit during operation Important safety instructions 10 Maintenan...

Page 21: ...automatici s p a The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Pe...

Page 22: ...ator name Date of job Technician s signature Requester s signature Job performed ________________________________________________________________________________________ ______________________________...

Page 23: ...ervice companies for proper disposal Prior to disposal it is always advisable to check speci c regulations in force in the place of disposal PLEASE DISPOSE OF PROPERLY 10 3 Problem solving MALFUNCTION...

Page 24: ...informaci n sobre la empresa los productos y asistencia en su idioma NL Voor meer informatie over het bedrijf de producten en hulp in uw eigen taal PT Para toda e qualquer informa o acerca da empresa...

Reviews: