Automatic closure
Set the time before automatic closure is activated, once the opening travel end point has been reached.
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a complete stop, during a power outage or if there is an
error.
F19
Automatic closure
0 =Deactivated (Default)
From 1 to 180 seconds
Pre-flashing time
Set the time for which the beacon is activated before each manoeuvre.
F21
Pre-flashing time
0 =Deactivated (Default)
1 to 10 seconds
Operating time
Set the gearmotor working time during opening and closing.
F22
Operating time
5 to 120 seconds (default 20 seconds)
Courtesy time
Set the lighting device operation time.
F25
Courtesy time
60 to 180 seconds (Default 180 seconds)
Opening and closing speed
Set the opening and closing speed.
For booms complete with accessories (swing rest and/or skirt), reduce the speed.
F28
Opening and closing speed
MIN = minimum speed (Default)
MED = average speed
MAX = maximum speed
XMA = maximum speed for boom <3m
Slow-down speed
Set the slowdown speed.
F30
Slow-down speed
MIN = minimum slowdown speed (Default)
MED = average slowdown speed
MIN = maximum slowdown speed
Calibration speed
Set the travel self-learning speed (percentage of maximum speed) and first manoeuvre speed
F33
Calibration speed
20% to 30%
Travel sensitivity
Adjust the obstruction detection sensitivity during boom travel.
F34
Travel sensitivity
10% to 100% (Default 100%) - 10% = maximum sensitivity - 100% = minimum sensitivity