Functions mapping
F 1
Total stop function (1-2)
F 2
Function associated with CX input
F 3
Function associated with CY input
F 5
Safety test function
F 6
Hold-to-run function
F 9
Obstruction detection function with motor idle
F 10
Function associated with the open-barrier signal output
F 11
Exclude encoder
F 14
Sensor type selection function
F 15
Luminous cord intermittence function
F 18
Additional light function
F 19
Automatic closing time
F 21
Pre-flashing time
F 22
Working time
F 25
Courtesy light time
F 28
Opening speed adjustment
F 29
Closing speed adjustment
F 30
Opening slow-down speed adjustment
F 31
Closing slow-down speed adjustment
F 33
Calibration speed adjustment
F 34
Sensitivity during travel
F 35
Sensitivity during slow-down
F 37
Adjustment of opening slow-down starting point
F 38
Adjustment of closing slow-down starting point
F 49
Managing serial connection
F 50
Save data to the memory roll
F 51
Read data on the memory roll
F 52
Parameter transfer from Master to Slave
F 56
Peripheral number
F 60
Sleep mode
F 61
Pre-flashing function
F 63
Change COM speed
U 1
Entering a user with an associated command
U 2
Delete a single user
U 3
Delete all users
A 1
Set boom type
A 2
Motor test
A 3
Travel calibration
A 4
Parameter reset
A 5
Manoeuvre count
H 1
Software version
Functions menu
IMPORTANT! Start programming these functions first: SET BOOM TYPE (A1), MOTOR TEST (A2), TOTAL STOP (F1) and TRAVEL
CALIBRATION (A3).
F1 Total stop [1-2]
0 = Deactivated (
default
) / 1 = Activated
N.C. Input – Stop barrier while excluding automatic closing; to resume movement, use the command device. The safety device should be
inserted in [1-2].
F2 Input
[2-CX]
0 = Deactivated (
default
) / 1 = C1 / 4 = C4 / 5 = C5 / 9 = C9
N.C. Input – Possible associations: C1 = reopening during closing by photocells, C4 = obstacle stand-by, C5 = immediate closure,
C9 = immediate closure with obstacle stand-by during closing.
F3 Input
[2-CY]
0 = Deactivated (
default
) / 1 = C1 / 4 = C4 / 5 = C5 / 9 = C9
N.C. Input – Possible associations: C1 = reopening during closing by photocells, C4 = obstacle stand-by, C5 = immediate closure,
C9 = immediate closure with obstacle stand-by during closing.
F5 Safety
test
0 = Deactivated (
default
) / 1 = CX / 2 = CY / 3 = CX+CY
After each opening and closing command, the board checks that the photocells are working correctly.