ENGLISH
P
age
1
5
1
5
- M
a
nu
a
l C
o
d
e:
1
1
9
G
V
2
2
1
1
9
G
V22 v
e
r.
2
.1
2.
1
12
/2
0
11
© C
A
M
E
c
a
n
ce
lli a
u
to
mati
ci
S
.p.
a
. - T
h
e d
a
ta a
n
d i
n
fo
rm
ati
o
n
i
n
thi
s ma
nu
a
l ma
y b
e c
h
a
n
g
e
d at a
n
y time a
n
d with
o
ut o
b
lig
a
ti
o
n
o
n
the p
a
rt
of C
a
me C
a
n
ce
lli A
u
to
mati
ci
S
.p.
a
. to n
o
tify s
a
id
c
h
a
n
g
e
s.
WARNING! The release
action may result in danger for
the user, when, for whatever
reason - the arm is impro-
perly fixed to the pin during
mounting, the arm is broken
or cracked during an accident,
etc! - the tension springs
no longer provide balance!
This may result in sudden
rotating movements of arm
attachment and/or of the
arm itself
.
- Insert the key into the lock and turn it clockwise. Manually lift the barrier arm and re-lock it by turning the key counter-clockwise.
Description of the control panel
Manual release of the barrier arm
Technical data
Designed and made by CAME Cancelli Automatici S.p.A.
The control panel is powered by 230 V AC, at 50 / 60 Hz frequen-
cy.
the command devices and accessories are powered by 24V. War-
ning!! The accessories must not exceed 40 W overall.
The control panel features an amperometric device whih constantly
controls the motor thrust data.
When the barrier arm runs into an obstacle, the amperometric sen-
sor detects an overload in the thrust and acts on the movement:
- when opening: by stopping the arm;
- when closing: by inverting the direction of travel and opens entirely;
the automatic closing activates.
Warning! a fter three consecutive inversions, the barrier arm stays
open and excludes automatic closing: to close press the command
button or transmitter key.
All connections are protected by quick fuses, see table.
The card handles the following functions:
- automatic closing after an opening command;
- immediate closing;
prefl ashing of the fl ashing light;
- obstacle detection when barrier arm is stopped in any position;
- Slave function;
- increased braking action of the barrier arm.
F U S E TA B L E
to protect:
fuses for:
Electronic card (line)
3.15 A-F
24 V Accessories
2 A-F
Command devices (control panel)
630 mA-F
Motor
10 A-F
T E C H N I C A L D ATA
power source
230 V - 50/60 Hz
max power
400 W
power draw when idle
110 mA
maximum power for 24 V accessories
40 W
circuit insulation class
II
container material
ABS
container protection rating
IP54
working temperature
-20 / +55°C
Types of command:
- opening/closing;
-opening/closing with maintained action;
- opening;
- total stop.
Specifi ci trimmer regolano:
- the working time for automatic closing;
- the sensitivity of the amperometric device;
Optional accessories:
- Flashing light and luminous cord.
- warning light for barrier arm open, turns off when arm is closed;
- 001LB38 card for emergency operation in case of blackouts and
battery charging (see technical documentation for 002LB38 card).
Warning! Before doing any work on the control panel,
cut off the main power and/or disconnect the batteries.
Summary of Contents for G6500
Page 29: ...B a r r i e r l i n e G6500 SERIES GARD INSTALLATION MANUAL STREET BARRIERS English EN 9 1...
Page 85: ...B a r r i e r l i n e G6500 GARD RU 9 RU...
Page 94: ...362 mm 10 10 119 G V 22 119 G V 22 2 1 2 1 12 2011 2011 CAME cancelli automatici s p a 6500...
Page 96: ...12 12 119 G V 22 119 G V 22 2 1 2 1 12 2011 2011 CAME cancelli automatici s p a...
Page 107: ...CA ME 2 3 2 3 119 G V 22 119 G V 22 2 1 2 1 12 2011 12 2011 CAME cancelli automatici s p a...
Page 111: ...27 27 119 G V 22 119 G V 22 2 1 2 1 12 2011 12 2011 CAME cancelli automatici s p a...