New user
Register up to a maximum of 250 users and assign a function to each one.
The operation can be carried out by using a transmitter or another control device. The boards that manage the control devices (AF - R700 - R800) must
be inserted into the connectors.
Manage users
New user
Step-by-step
Sequential
Open
Partial opening
When the barrier is in [Paired] mode, the [Partial Opening] command opens the
Master barrier.
Choose the function to be assigned to the user.
Press ENTER to confirm.
Send the code from the control device.
Repeat the procedure to add other users.
Remove user
Remove one of the registered users.
Manage users
Remove user
Confirm? NO
Confirm? YES
Use the arrows to choose the number associated with the user you want to remove.
No. 1 > 250
Alternatively, the control device associated with the user you want to remove can be
activated.
Press ENTER to confirm.
“CLr” will appear to confirm deletion.
Remove all
Remove all registered users.
Manage users
Remove all
Confirm? NO
Confirm? YES
Radio decoding
Choose the type of radio coding for the transmitters enabled to control the operator.
If you choose the type of radio coding for the transmitters [Rolling code] or [TW key block], any transmitters with a different type of radio coding saved
previously will be deleted.
Manage users
Radio decoding
All decoding (Default)
Rolling code
TW Key block
Confirm? NO
Confirm? YES
Boom length
Set the boom length.
Configuration>
Motor settings
Boom length
Up to 3 m
Up to 4 m
Jointed boom