ERROR MESSAGES
Calibration error
Interruption of the boom travel calibration due to the presence of an obstruction.
The Encoder does
not work
The Encoder is disconnected.
The Encoder is broken.
Service test failure
error
Presence of an obstruction within the range of the photocells.
The photocells are not correctly connected or configured.
The photocells are faulty.
Work time expired
Finished the maximum work time set.
Door lock open
The operator is released.
Maximum number
of closing obstacles
The maximum number of obstacles detected consecutively has been exceeded
Maximum number
of opening obstacles
The maximum number of obstacles detected consecutively has been exceeded
Maximum number
of obstacles
The maximum number of obstacles detected consecutively has been exceeded
Serial
communication
error
Configured on the wrong RSE port.
Incompatible remote
control
The transmitter used is not CAME.
The coding set is different from that of the transmitter.
The transmitters are TWIN and have different KEY BLOCK.
Slave door open
The SLAVE operator is released.
Detached boom
The boom was pushed open.
Incorrect ARM contact wiring.
No boom detection sensor.
Released motor
The boom has been released by the gearmotor and it can be moved manually.
Open gearmotor safety microswitch contact.