CZ input
Associate a function with the CZ input.
F4
CZ input
OFF (Default)
C1 = Reopening while closing (Photocells)
C4 = Obstacle wait (Photocells)
C5 = Immediate closing at the opening travel end
C7 = Reopening while closing (sensitive safety-edges)
C9 = immediate closing at the travel end during opening with obstacle waiting, during
closing
C10 = Immediate closing during opening with obstacle waiting during closing
r7 = reopening while closing (sensitive safety-edges with 8K2 resistor)
Safety devices test
It activates the check of the correct operation of the photocells connected to the inputs, after each opening and closing command.
F5
Safety devices test
OFF (Default)
1 = CX
2 = CY
3 = CZ
4 = CX+CY
5 = CX+CZ
6 = CY+CZ
7 = CX+CY+CZ
Maintained action
With the function active, the operator movement (opening or closing) is interrupted when the control device is released.
Activation of the function excludes all other control devices.
F6
Maintained action
OFF (Default)
ON
Obst. with motor stopped
With the function active, the boom remains stopped if the safety devices detect an obstacle. The function activates with: closed rod, open rod or after a total stop.
F9
Obst. with motor stopped
OFF (Default)
ON
Open warning light
It warns of the state of the barrier.
F10
Open warning light
0 = Warning light on (Default) - The light stays on when the boom is moving or open.
1 = Warning light flashing - The warning light flashes every half second when the
boom is opening and stays on when the boom is open. The light flashes every second
when the boom is closing and is off when the boom is closed.
Sensor type
It sets the type of control device.
F14
Sensor type
0 = Transponder
1 = Keypad (Default)