background image

p. 

21

 - Manual 

FA01354-EN

  - 07/2019 - © C

AME S.p.A. - The cont

ents of this manual may change, at any time, and without notice. - Original instructions

RSE1

Configures the function to be performed by the board connected to the RSE1 connector.

F49

RSE1

OFF (Default)
1 = Combined
4 = Compass

Saving data

It saves user data, timings and configurations to the memory device (memory roll or USB key).

 The function is displayed only when a USB memory stick is inserted into the USB port or when a memory roll is inserted into the control board.

F50

Saving data

OFF (Default)
ON

Data reading

It uploads user data, timings and configurations from the memory device (memory roll or USB key).

 The function is displayed only when a USB memory stick is inserted into the USB port or when a memory roll is inserted into the control board.

F51

Data reading

OFF (Default)
ON

Transferring MASTER-SLAVE parameters

It enables to share the parameters programmed on the Master barrier with the Slave barrier.

 This only appears if the F49 function is set to Paired or Alternate.

F52

Transferring MASTER-SLAVE 
parameters

OFF (Default)
ON

Opening direction

Set the boom opening direction.

F54

Opening direction

0 = To the left (Default)
1 = To the right

CRP address

It assigns a unique identification code (CRP address) to the control board. The function is necessary if there are more operators connected by CRP.

F56

CRP address

from 1 to 255

RSE speed

Sets the remote connection system communication speed on the RSE1 port.

F63

RSE speed

0 = 1200 bps
1 = 2400 bps
2 = 4800 bps
3 = 9600 bps
4 = 14400 bps
5 = 19200 bps
6 = 38400 bps (Default)
7 = 57600 bps
8 = 115200 bps

Summary of Contents for GARD PT Series

Page 1: ...Automatic road barriers GARD PT Brushless GPT40AGS GPT40RGS INSTALLATION MANUAL FA01354 EN EN English...

Page 2: ...e correct boom fastening and conditions have been compromised by an accident or by installation errors In these cases the tensioned springs no longer guarantee the boom balancing which could suddenly...

Page 3: ...tely cut off the power supply according to category III surcharge conditions Demarcate properly the entire site to prevent unauthorized personnel to enter especially children and minors In case of man...

Page 4: ...F THE PACKAGING The packaging materials cardboard plastic and so on should be disposed of as solid household waste and simply separated from other waste for recycling Always make sure you comply with...

Page 5: ...otor painted aluminium cabinet GPT40RGS Automatic barrier with reversible gearmotor and brushless motor painted aluminium cabinet Intended use The ideal solution for passage ways with heavy transit fl...

Page 6: ...ard for NC contact for boom drop away 16 Terminal board for NC contact for gearmotor release 17 Terminal block associated with the RSE_2 connector for CRP or CAME KEY connection 18 Terminal block asso...

Page 7: ...hermal protection C 120 120 Current draw mA 1 5 230 V AC 2 8 120 V AC Working temperature C 20 55 20 55 Torque Nm 80 with no springs 140 with springs 80 with no springs 140 with springs Opening time a...

Page 8: ...pe H05RN F with designation 60245 IEC 57 For installation in an indoor environment use cables with properties equivalent to at least those of type H05VV F designation to 60227 IEC 53 If cable lengths...

Page 9: ...s not allow for a sturdy fastening of the device you will have to set up a cement slab Dig a hole for the foundation frame Set up the corrugated tubes needed for the wiring coming out of the junction...

Page 10: ...e and without notice Original instructions Fill the hole with earth around the concrete block Remove the nuts from the bolts Fit the electric cables into the tubes so that they come out about 1500 mm...

Page 11: ...pening direction The barrier is set up for installing on the left 1 Check that the lever arm is positioned vertically 2 Remove the mechanical stop 3 Attach the mechanical stop to the right of the leve...

Page 12: ...er profile into the groove of the boom closing cap Use the screws to fasten the boom end cap 7 Fit the anti shearing protective cover onto the boom attachment cover and fasten it using the screws supp...

Page 13: ...en it is in the open position Correct the boom s horizontal position Release the gearmotor Open the inspection hatch 1 Turn the mechanical stop until the desired position of the boom is achieved 2 Fas...

Page 14: ...e wiring made The cables must pass through the ferrite included in the supply 1 1 Input voltage Make sure the mains power supply is disconnected during all installation procedures Before working on th...

Page 15: ...ut must not exceed 40 W Signalling devices 1 Additional light Increases illumination in the maneuvering area 2 Additional flashing light It flashes during the operator opening and closing phases 3 Ope...

Page 16: ...he contact must be used only for operators working in paired mode 8 Control device CLOSE ONLY function NO contact For closing only The contact can be programmed for the hold to run function 9 Control...

Page 17: ...n be connected DIR DELTA S photocells Connection with safety test Multiple photocell pairs can be connected See function F5 safety devices test 2 10 S1GND A B 11 E1 E6 TS 1 2 3 3P 4 5 7 2 CX CY CZ FA...

Page 18: ...fault ON CX input It associates a function with the CX input F2 CX input OFF Default C1 Reopening while closing Photocells C4 Obstacle wait Photocells C5 Immediate closing at the opening travel end C7...

Page 19: ...lt 1 CX 2 CY 3 CZ 4 CX CY 5 CX CZ 6 CY CZ 7 CX CY CZ Maintained action With the function active the operator movement opening or closing is interrupted when the control device is released Activation o...

Page 20: ...g is activated once the opening travel end has been reached The function does not work if any of the safety devices trigger when an obstacle is detected or after a total stop or during a power outage...

Page 21: ...B memory stick is inserted into the USB port or when a memory roll is inserted into the control board F51 Data reading OFF Default ON Transferring MASTER SLAVE parameters It enables to share the param...

Page 22: ...be programmed to operate in C5 C9 C10 mode at the end of the count the passage is closed F75 Opening counter OFF Default ON Boom drop away detection It activate the contact on the ARM terminal block f...

Page 23: ...m Default 2 from 2 5 to 3 8 m Motor test Verification of the correct opening direction of the boom If the keys do not execute the commands correctly invert the boom opening direction A2 Motor test ON...

Page 24: ...r to be completed Immediately press the STOP button if any suspicious malfunctions noises or vibrations occur in the system If the display indicator LED flashes this means that the electronic board ha...

Page 25: ...p 25 Manual FA01354 EN 07 2019 CAME S p A The contents of this manual may change at any time and without notice Original instructions FINAL OPERATIONS...

Page 26: ...11 E1 E6 TS 1 2 3 3P 4 5 7 2 CX CY CZ FA FC FCA CM1 FCC CM2 EB MOTOR BLOCK ARM RSE A B GND A B GND R G B 2 24 1 2 3 3P 4 5 7 2 CX CY CZ 0 30 0 FA FC TAMPER FCA CM1 FCC CM2 EB MOTOR BLOCK ARM EB RSE UT...

Page 27: ...rical connections of the devices and accessories see the ELECTRICAL CONNECTIONS chapter The control and safety devices must be connected on both electronic boards A B GND A B GND R G B 2 10 S1 GND A B...

Page 28: ...4 EN 07 2019 CAME S p A The contents of this manual may change at any time and without notice Original instructions 2 ONLY OPEN command 2 3 on barrier B 2 OPEN CLOSE command 2 7 on barrier A or B for...

Page 29: ...ual For information about product and accessory choice browse the products catalog If the barrier with articulated joint is used check that the movement elements of the joint are in good condition and...

Page 30: ...cted during opening E11 Exceeded the maximum number of obstacles consecutively detected E14 Serial communication error E15 Incompatible transmitter error E16 Open SLAVE motor hatch error E20 Arm boom...

Page 31: ...p 31 Manual FA01354 EN 07 2019 CAME S p A The contents of this manual may change at any time and without notice Original instructions...

Page 32: ...07 2019 CAME S p A The contents of this manual may change at any time and without notice Original instructions CAME S p A Via Martiri della Libert 15 31030 Dosson di Casier Treviso Italy Tel 39 0422...

Reviews:

Related manuals for GARD PT Series