p.
21
- Manual
FA01354-EN
- 07/2019 - © C
AME S.p.A. - The cont
ents of this manual may change, at any time, and without notice. - Original instructions
RSE1
Configures the function to be performed by the board connected to the RSE1 connector.
F49
RSE1
OFF (Default)
1 = Combined
4 = Compass
Saving data
It saves user data, timings and configurations to the memory device (memory roll or USB key).
The function is displayed only when a USB memory stick is inserted into the USB port or when a memory roll is inserted into the control board.
F50
Saving data
OFF (Default)
ON
Data reading
It uploads user data, timings and configurations from the memory device (memory roll or USB key).
The function is displayed only when a USB memory stick is inserted into the USB port or when a memory roll is inserted into the control board.
F51
Data reading
OFF (Default)
ON
Transferring MASTER-SLAVE parameters
It enables to share the parameters programmed on the Master barrier with the Slave barrier.
This only appears if the F49 function is set to Paired or Alternate.
F52
Transferring MASTER-SLAVE
parameters
OFF (Default)
ON
Opening direction
Set the boom opening direction.
F54
Opening direction
0 = To the left (Default)
1 = To the right
CRP address
It assigns a unique identification code (CRP address) to the control board. The function is necessary if there are more operators connected by CRP.
F56
CRP address
from 1 to 255
RSE speed
Sets the remote connection system communication speed on the RSE1 port.
F63
RSE speed
0 = 1200 bps
1 = 2400 bps
2 = 4800 bps
3 = 9600 bps
4 = 14400 bps
5 = 19200 bps
6 = 38400 bps (Default)
7 = 57600 bps
8 = 115200 bps