background image

p. 

3

 - Manual 

FA01354-EN

  - 07/2019 - © C

AME S.p.A. - The cont

ents of this manual may change, at any time, and without notice. - Original instructions

GENERAL PRECAUTIONS FOR INSTALLERS

 Important safety instructions.

 Follow all of these instructions. Improper installation can cause serious bodily harm.

 Before continuing, also read the general precautions for users.

Use this product only for its specifically intended use. Any other use is hazardous. • The manufacturer can not be held 

liable for any damage caused by improper, unreasonable, and erroneous use. • This manual's product is defined by the 

Machinery Directive 2006/42/CE as partly-completed machinery. • Partly-completed machinery is an assembly that 

almost constitutes a machine, but which, alone, cannot ensure a clearly defined application. • Partly-completed machinery 

is only destined to be incorporated or assembled to other machinery or other partly-completed machinery or apparatuses 

to build machinery that is regulated by the Machinery Directive 2006/42/EC. • The final installation must comply with the 

Machinery Directive 2006/42/EC and the current European reference standards. • The manufacturer declines any liability 

for using non-original products; which would result in warranty loss. • All operations indicated in this manual must be 

carried out exclusively by skilled and qualified personnel and in full compliance with current regulations. • Laying of cables, 

installation and testing must follow state-of-the-art procedures as dictated by applicable standards and laws. • Make sure 

the mains power supply is disconnected during all installation procedures. • Check that the temperature ranges given and 

those of the location match. • Make sure that the opening automatic barrier does not constitute a hazard. • Do not install 

on slopes, that is, on any surfaces that are not perfectly level • If necessary, add suitable reinforcements to the anchoring 

points. If necessary, add suitable reinforcements to the anchoring points. • Make sure that the operator, in the installation 

place, does not get wet by direct jets of water (sprinklers, water cleaners, etc.). • Make sure you have set up a suitable 

dual pole cut off device along the power supply that is compliant with the installation rules. It should completely cut off the 

power supply according to category III surcharge conditions. • Demarcate properly the entire site to prevent unauthorized 

personnel to enter; especially children and minors. • In case of manual handling, have one person for every 20 kg that 

need hoisting; for non manual handling use proper hoisting equipment in safe conditions. • During the fixing phases, 

the operator could be unstable and overturn. Be careful and do not lean on it until it is fully fastened. • Use suitable 

protections to prevent any mechanical hazards due to persons loitering within the operating range of the operator. • The 

electric cables must pass through special pipes, ducts and cable glands in order to guarantee adequate protection against 

mechanical damage. • Make sure that the moving mechanical elements have adequate distance from the wiring made. • 

The electrical cables must not touch any parts that may overheat during use (such as the motor and the transformer). • All 

fixed controls must be clearly visible after installation, in position that the guided part is directly visible, but far away from 

moving parts. In the case of a maintained action command, this must be installed at a minimum height of 1.5 m from the 

ground and must not be accessible to the public. • When the passage width clearance is greater than 3 m, you must use a 

fixed rest for the boom to support it. • If not already present, apply a permanent tag, that describes how to use the manual 

release mechanism, close to the mechanism. • Make sure that the operator has been properly adjusted and that the safety 

and protection devices, and the manual release, are working properly. • Before turning over to the final user, check that 

the system complies with the harmonized standards and the essential requisites of Machinery Directive 2006/42/CE. • 

Any residual risks must be indicated clearly with proper signage affixed in visible areas. All of which must be explained 

to end users. • Fit, in plain sight, the machine's ID plate when the installation is complete. • If the power-supply cable is 

damaged, it must be immediately replaced by the manufacturer or by an authorized technical assistance center, or in any 

case, by qualified staff, to prevent any risk. • Keep this manual inside the technical folder along with the manuals of all the 

other devices used for your automation system. • Remember to hand over to the end users all the operating manuals of 

the products that make up the final machinery.

Summary of Contents for GARD PT Series

Page 1: ...Automatic road barriers GARD PT Brushless GPT40AGS GPT40RGS INSTALLATION MANUAL FA01354 EN EN English...

Page 2: ...e correct boom fastening and conditions have been compromised by an accident or by installation errors In these cases the tensioned springs no longer guarantee the boom balancing which could suddenly...

Page 3: ...tely cut off the power supply according to category III surcharge conditions Demarcate properly the entire site to prevent unauthorized personnel to enter especially children and minors In case of man...

Page 4: ...F THE PACKAGING The packaging materials cardboard plastic and so on should be disposed of as solid household waste and simply separated from other waste for recycling Always make sure you comply with...

Page 5: ...otor painted aluminium cabinet GPT40RGS Automatic barrier with reversible gearmotor and brushless motor painted aluminium cabinet Intended use The ideal solution for passage ways with heavy transit fl...

Page 6: ...ard for NC contact for boom drop away 16 Terminal board for NC contact for gearmotor release 17 Terminal block associated with the RSE_2 connector for CRP or CAME KEY connection 18 Terminal block asso...

Page 7: ...hermal protection C 120 120 Current draw mA 1 5 230 V AC 2 8 120 V AC Working temperature C 20 55 20 55 Torque Nm 80 with no springs 140 with springs 80 with no springs 140 with springs Opening time a...

Page 8: ...pe H05RN F with designation 60245 IEC 57 For installation in an indoor environment use cables with properties equivalent to at least those of type H05VV F designation to 60227 IEC 53 If cable lengths...

Page 9: ...s not allow for a sturdy fastening of the device you will have to set up a cement slab Dig a hole for the foundation frame Set up the corrugated tubes needed for the wiring coming out of the junction...

Page 10: ...e and without notice Original instructions Fill the hole with earth around the concrete block Remove the nuts from the bolts Fit the electric cables into the tubes so that they come out about 1500 mm...

Page 11: ...pening direction The barrier is set up for installing on the left 1 Check that the lever arm is positioned vertically 2 Remove the mechanical stop 3 Attach the mechanical stop to the right of the leve...

Page 12: ...er profile into the groove of the boom closing cap Use the screws to fasten the boom end cap 7 Fit the anti shearing protective cover onto the boom attachment cover and fasten it using the screws supp...

Page 13: ...en it is in the open position Correct the boom s horizontal position Release the gearmotor Open the inspection hatch 1 Turn the mechanical stop until the desired position of the boom is achieved 2 Fas...

Page 14: ...e wiring made The cables must pass through the ferrite included in the supply 1 1 Input voltage Make sure the mains power supply is disconnected during all installation procedures Before working on th...

Page 15: ...ut must not exceed 40 W Signalling devices 1 Additional light Increases illumination in the maneuvering area 2 Additional flashing light It flashes during the operator opening and closing phases 3 Ope...

Page 16: ...he contact must be used only for operators working in paired mode 8 Control device CLOSE ONLY function NO contact For closing only The contact can be programmed for the hold to run function 9 Control...

Page 17: ...n be connected DIR DELTA S photocells Connection with safety test Multiple photocell pairs can be connected See function F5 safety devices test 2 10 S1GND A B 11 E1 E6 TS 1 2 3 3P 4 5 7 2 CX CY CZ FA...

Page 18: ...fault ON CX input It associates a function with the CX input F2 CX input OFF Default C1 Reopening while closing Photocells C4 Obstacle wait Photocells C5 Immediate closing at the opening travel end C7...

Page 19: ...lt 1 CX 2 CY 3 CZ 4 CX CY 5 CX CZ 6 CY CZ 7 CX CY CZ Maintained action With the function active the operator movement opening or closing is interrupted when the control device is released Activation o...

Page 20: ...g is activated once the opening travel end has been reached The function does not work if any of the safety devices trigger when an obstacle is detected or after a total stop or during a power outage...

Page 21: ...B memory stick is inserted into the USB port or when a memory roll is inserted into the control board F51 Data reading OFF Default ON Transferring MASTER SLAVE parameters It enables to share the param...

Page 22: ...be programmed to operate in C5 C9 C10 mode at the end of the count the passage is closed F75 Opening counter OFF Default ON Boom drop away detection It activate the contact on the ARM terminal block f...

Page 23: ...m Default 2 from 2 5 to 3 8 m Motor test Verification of the correct opening direction of the boom If the keys do not execute the commands correctly invert the boom opening direction A2 Motor test ON...

Page 24: ...r to be completed Immediately press the STOP button if any suspicious malfunctions noises or vibrations occur in the system If the display indicator LED flashes this means that the electronic board ha...

Page 25: ...p 25 Manual FA01354 EN 07 2019 CAME S p A The contents of this manual may change at any time and without notice Original instructions FINAL OPERATIONS...

Page 26: ...11 E1 E6 TS 1 2 3 3P 4 5 7 2 CX CY CZ FA FC FCA CM1 FCC CM2 EB MOTOR BLOCK ARM RSE A B GND A B GND R G B 2 24 1 2 3 3P 4 5 7 2 CX CY CZ 0 30 0 FA FC TAMPER FCA CM1 FCC CM2 EB MOTOR BLOCK ARM EB RSE UT...

Page 27: ...rical connections of the devices and accessories see the ELECTRICAL CONNECTIONS chapter The control and safety devices must be connected on both electronic boards A B GND A B GND R G B 2 10 S1 GND A B...

Page 28: ...4 EN 07 2019 CAME S p A The contents of this manual may change at any time and without notice Original instructions 2 ONLY OPEN command 2 3 on barrier B 2 OPEN CLOSE command 2 7 on barrier A or B for...

Page 29: ...ual For information about product and accessory choice browse the products catalog If the barrier with articulated joint is used check that the movement elements of the joint are in good condition and...

Page 30: ...cted during opening E11 Exceeded the maximum number of obstacles consecutively detected E14 Serial communication error E15 Incompatible transmitter error E16 Open SLAVE motor hatch error E20 Arm boom...

Page 31: ...p 31 Manual FA01354 EN 07 2019 CAME S p A The contents of this manual may change at any time and without notice Original instructions...

Page 32: ...07 2019 CAME S p A The contents of this manual may change at any time and without notice Original instructions CAME S p A Via Martiri della Libert 15 31030 Dosson di Casier Treviso Italy Tel 39 0422...

Reviews: