p.
7
- Manual
FA01354-EN
- 07/2019 - © C
AME S.p.A. - The cont
ents of this manual may change, at any time, and without notice. - Original instructions
Dimensions
250
206.5
3800 max
20
884
1133
1117
276
170
Limits to use
MODELS
GPT40AGS
GPT40RGS
Maximum clearance width of the passage (m)
3,8
3,8
Technical data
MODELS
GPT40AGS
GPT40RGS
Power supply (V - 50/60 Hz)
230 AC 50/60Hz
120 AC 50/60Hz
Motor power supply (V)
36 DC
36 DC
Stand-by consumption (W)
12
12
Power (W)
350
350
Transformer thermal protection (°C)
120
120
Current draw (mA)
1.5 (230 V AC)
2,8 (120 V AC)
Working temperature (°C)
-20 ÷ +55
-20 ÷ +55
Torque (Nm)
80 (with no springs)
140 (with springs)
80 (with no springs)
140 (with springs)
Opening time at 90° (s)
1,2 ÷ 4
1,2 ÷ 4
Duty cycle (%)
CONTINUOUS DUTY (with springs and boom up to
3.8 m) - INTENSIVE DUTY (without springs and with
boom up to 2.5 m)
CONTINUOUS DUTY (with springs and boom up to
3.8 m) - INTENSIVE DUTY (without springs and with
boom up to 2.5 m)
Protection rating (IP)
54
54
Insulation class
I
I
Weight (kg)
37
37
Fuse table
MODELS
GPT40AGS
GPT40RGS
Line fuse
3.15 A F
6,3 A F
Accessories fuse
2 A F
2 A F
Control board fuse
3.15 A F
3.15 A F
Motor fuse
15 A F
15 A F