P
age
5
- Manual
FA01610-EN
- 08/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
PRODUCT DATA AND INFORMATION
Key
This symbol shows which parts to read carefully.
This symbol shows which parts describe safety issues.
This symbol shows what to tell users.
The measurements, unless otherwise stated, are in millimetres.
Description
803BB-0120
GPX40MGS - Automatic barrier with irreversible gearmotor and brushless motor; painted galvanised steel cabinet.
803BB-0130
GPX40MGC - Automatic barrier with irreversible gearmotor and brushless motor; painted galvanised steel cabinet. Model suitable for areas exposed to high
temperatures.
803BB-0100
GPX40MGP - Automatic barrier with irreversible gearmotor and brushless motor; painted galvanised steel cabinet. Supplied complete with: 009SMA and an
interface for direct connection to an entrance/exit post for PKE and PKM parking systems.
803BB-0150
GPX40MCP - Automatic barrier with irreversible gearmotor and brushless motor; galvanised steel cabinet painted in a personalised RAL colour. Supplied complete
with: 009SMA and an interface for direct connection to an entrance/exit post for PKE and PKM parking systems.
803BB-0340
GPX40MXP - Automatic barrier with irreversible gearmotor and brushless motor; painted AISI 430 steel cabinet. Supplied complete with: 009SMA and an interface
for direct connection to an entrance/exit post for PKE and PKM parking systems.
Intended use
The ideal solution for passage ways with heavy transit flows
Any installation and/or use other than that specified in this manual is forbidden..
Usage limitations
MODELS
GPX40MGS
GPX40MGC
GPX40MGP
GPX40MCP
GPX40MXP
Max. net clearance width (m)
3,8
3,8
3,8
3,8
3,8
Technical data
MODELS
GPX40MGS
GPX40MGC
GPX40MGP
GPX40MCP
GPX40MXP
Power supply (V - 50/60 Hz)
100 AC to 240 AC
100 AC to 240 AC
100 AC to 240 AC
100 AC to 240 AC
100 AC to 240 AC
Motor power supply (V)
36 DC
36 DC
36 DC
36 DC
36 DC
Standby consumption (W)
2,5
2,5
3,3
3,3
3,3
Power (W)
270
270
270
270
270
Operating temperature (°C)
-20 to +55 (-40 with
item 803XA-0260)
-20 to +55 (-40 with
item 803XA-0260)
-20 to +55 (-40 with
item 803XA-0260)
-20 to +55 (-40 with
item 803XA-0260)
-20 to +55 (-40 with
item 803XA-0260)
Torque (Nm)
100
100
100
100
100
Opening time at 90° (s)
1 ÷ 2
1 ÷ 2
1 ÷ 2
1 ÷ 2
1 ÷ 2
Duty cycle (%)
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
Protection rating (IP)
54
54
54
54
54
Insulation class
I
I
I
I
I
Weight (kg)
62
62
62,5
62,5
62,5
Fuse table
MODELS
GPX40MGS
GPX40MGC
GPX40MGP
GPX40MCP
GPX40MXP
Line fuse
3.15 A F
3.15 A F
3.15 A F
3.15 A F
3.15 A F
Accessory fuse
2 A F
2 A F
2 A F
2 A F
2 A F
Cartridge heater fuse
1 A T
-
1 A T
1 A T
1 A T
Fan fuse
-
100 mA F
-
-
-