P
age
26
- Manual
FA01383-EN
- 04/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Light E1
Choose the type of device connected to the output.
F18
Light E1
0 =Flashing beacon (Default)
1 = Cycle light
This parameter does not appear if there [Automatic Close] function is
deactivated.
2 = Courtesy light.
The lighting device remains on for the time set for the [Courtesy time] function.
Automatic closure
Set the time before automatic closure is activated, once the opening travel end point has been reached.
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a complete stop, during a power outage or if
there is an error.
F19
Automatic closure
OFF (Default)
From 1 to 180 seconds
Pre-flashing time
Set the time for which the beacon is activated before each manoeuvre.
F21
Pre-flashing time
OFF (Default)
1 to 10 seconds
Courtesy time
Set the lighting device operation time.
F25
Courtesy time
60 to 180 seconds (Default 180 seconds)
Opening speed
Set the opening speed (percentage of maximum speed).
For booms complete with accessories (swing rest and/or skirt), reduce the speed.
F28
Opening speed
50% to 100% (Default 50%)
Closing speed
Set the closing speed (percentage of maximum speed).
For booms complete with accessories (swing rest and/or skirt), reduce the speed.
F29
Closing speed
30% to 100% (Default 30%)
Travel sensitivity
Adjust the obstruction detection sensitivity during boom travel.
F34
Travel sensitivity
10% to 100% (Default 100%) - 10% = maximum sensitivity - 100% = minimum
sensitivity