Pre-flashing
Choose the type of manoeuvre that activates the flashing beacon in advance.
Set how much earlier the flashing beacon is activated under the function [Pre-flashing time].
F61
Pre-flashing
0 = when opening and closing (Default)
1 = only when closing
2 = only when opening
RSE speed
Set the communication speed of the remote connection system on the RSE_1 and RSE_2 ports.
F63
rE1
rE2
2 = 4800 bps
3 = 9600 bps
4 = 14400 bps
5 = 19200 bps
6 = 38400 bps (default)
7 = 57600 bps
8 = 115200 bps
FCA FCC warnings
Configure the method with which the FCA and FCC outputs report the boom status.
F70
FCA FCC warnings
OFF (Default)
1 = Impulse
When the boom reaches the travel end point (while opening or closing), the FCA-CM1
or FCC-CM2 contact closes for one second.
2 = Steady
When the boom reaches the travel end point (while opening or closing), the FCA-CM1
or FCC-CM2 contact closes and remains closed.
3 = Custom
The FCA-CM1 contact is closed with the boom in the open travel end position and
during the opening manoeuvre. The FCC-CM2 contact is closed with the boom in the
closed travel end position and during the closing manoeuvre.
Opening counter
With the function active, you can send a series of opening commands corresponding to the number of vehicles which have to be authorised to pass through the
gate. The function can only be operated by control devices connected to the contact 2-3. The magnetic contact, to which the loop that counts vehicles in transit is
connected, is connected to an input. This input must be programmed to operate in C5/C9/C10 mode. At the end of the count the passage is closed.
F75
Opening counter
OFF (Default)
ON
Emergency battery operation
Emergency function in the event of a power outage. Batteries required.
F93
Emergency battery operation
OFF (Default)
Standard operation
1 = Immediate opening
In the event of a power outage, the operator runs an opening command within 1
minute and all other commands are blocked until power is restored.