WARNING!

Important instructions for the safety of people: 

READ CAREFULLY!

Foreword

• Use of the products must be restricted to its intended use 
(i.e. that for which it was expressly built for). Any other use is 
to be considered dangerous. Came Cancelli Automatici S.p.A. 
is not liable for any damage resulting from improper, wrongful 
or unreasonable use •  Keep these warnings with the installa-
tion and use manuals issued with the automated system.

Before installing 

(preliminary check: in case of a negative 

outcome, do not proceed before having 

complied with the safety obligations)

• Make sure that the parts you intend to automate are in 
good working order, and that they are  properly balanced 
and  aligned.  Also,  make  sure  that  proper  mechanical  stops 
are already in place • If the operator will be installed at a 
height of less than 2.5 m from the ground or other access 
level, check whether you will need any protections and/or 
warnings • Any gate leaves, fi tted with pedestrian entrances, 
onto which you will install an operator, must have a blocking 
mechanism when the gate is in motion • Make sure that the 
opening of the automated gate is not an entrapment hazard 
as regards any surrounding fi xed parts • Do not mount the 
operator upside down or onto any elements that may fold 
under its weight. If needed, add suitable reinforcements at 
the points where it is secured • Do not install onto gates on 
either an upward or downward slope (i.e. that are not on fl at, 
level ground) • Check that any lawn watering devices will not 
wet the gearmotor from the bottom up.

Installation

• Carefully section off the entire site to prevent unauthorised  
access, especially by minors and children • Be careful when 
handling operators that weigh more than 20 Kg (see installa-
tion manual). In such cases, employ proper weight handling 
safety equipment • All opening commands (e.g. buttons, key 
selectors, magnetic detectors, etc.) must be installed at least 
1.85 m from the gate’s area of operation perimeter - or where 
they cannot be reached from the outside of the gate. Also, 
the direct commands (e.g. push button, or proximity devices, 
etc.) must be installed at a height of at least 1.5 m and must 
not be accessible to the public • All ‘maintained action’ com-
mands, must be placed where the moving gate leaves, transit 
areas and driveways are completely visible • If missing, ap-
ply a permanent label that shows the position of the release 
mechanism • Before delivering to the client, verify that the 
system is EN 12453 (impact test) standard compliant. Make 
sure that the operator has been properly adjusted and that the 
safety and protection devices, as well as the manual release 

are working properly • Where necessary and in plain sight, 
apply the Warning Sings (e.g. gate plate).

Special instructions and 

advice for users

• Keep the gate’s area of operation clean and clear of any 
obstacles. Trim any vegetation that may interfere with the 
photocells • Do not allow children to play with the fi xed com-
mand  devices,  or  in  the  gate’s  area  of  operation.  Keep  any 
remote control devices (i.e. transmitters) away from the chil-
dren as well • Frequently check the system, to see whether 
any anomalies or signs of wear and tear appear on the moving 
parts, on the component parts, on the securing points, on the 
cables and any accessible connections. Keep any joints (i.e. 
hinges)  lubricated and clean, and do the same where fric-
tion may occur (i.e. slide rails) • Perform functional tests on 
photocells and sensitive edges, every six months. Keep glass 
panels constantly clean (use a slightly water-moistened cloth; 
do not use solvents or any other chemical products) • If the 
system requires repairs or modifi cations, release the operator 
and do not use it until safety conditions have been restored 
• Cut off the power supply before releasing the operator for 
manual openings. See instructions • Users are FORBIDDEN 
to carry out ANY ACTIONS THAT THEY HAVE NOT BEEN 
EXPRESSLY ASKED TO DO OR SO INDICATED in the manu-
als. Any repairs, modifi cations to the settings and extraor-
dinary maintenance MUST BE DONE BY THE TECHNICAL 
ASSISTANCE STAFF • On the periodic maintenance log, note 
down the checks you have done.

Special instructions and 

advice for all

• Avoid working near the hinges or moving mechanical parts 
• Stay clear of the gate’s area of operation when in motion • 
Do not resist the direction of movement of the gate; this may 
present a safety hazard • At all times be extremely careful 
about dangerous points that must be indicated by proper 
pictograms and/or black and yellow stripes • When using 
a selector or command in ‘maintained action’ mode, keep 
checking that there are no people in the area of operation of 
the moving parts. Do this until you release the command • 
The gate may move at any time without warning • Always cut 
the power when cleaning performing maintenance. 

EN

Intelligent Security & Fire Ltd.

Summary of Contents for GUARDIAN Series

Page 1: ...GUARDIAN SERIES INSTALLATION MANUAL PSHPS01 PSHPS07 PSHPSD7 FULL HEIGHT TURNSTILE English EN I n t e l l i g e n t S e c u r i t y F i r e L t d...

Page 2: ...e leaves transit areas and driveways are completely visible If missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system...

Page 3: ...howing the company s written authorisation to accept the returned goods including the quality and quantity of the returned goods The returned goods shall not be accepted by the company unless carried...

Page 4: ...he mechanism has an antirotation system that is activated once the rotor arms extend beyond 60 The complete range PSHPS01 Full height mono directional single opening mechanical turnstile Body made of...

Page 5: ...installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH mm 4 3 Description of parts 1 Supporting column 2 Transom 3...

Page 6: ...ols 5 2 Tools and materials Before installing the automated device please Set up a proper omnipolar cut off device with contacts more than 3 mm apart and power source isolation Set up proper tubing an...

Page 7: ...om the junction pit N B the number of tubes depends on the type of installation and accessories being fitted Warning to install this at least two or three people are needed Use hoisting equipment to m...

Page 8: ...CAME cancelli automatici s p a to notify users ENGLISH Use the template to precisely mark the holes for securing the columns and wings Drill the carefully marked holes using a 12 mm bit and secure the...

Page 9: ...tify users ENGLISH Assemble the rotor arms join and secure the single arms to the side with bolts and to the reinforcing triangle with the washers nuts and bolts using the issued T driver Finally inse...

Page 10: ...rt the upper centre swivel pin of the rotor arms into the hole in the traverse piece insert the Seeger ring into the swivel pin housing and leave the rotor arms hanging from the traverse piece suspend...

Page 11: ...to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Secure the arms to the frames using washers and nuts Then insert the caps Secure the armed frame...

Page 12: ...ion on CAME cancelli automatici s p a to notify users ENGLISH Warning Position the cage s upper swing pin as shown in the drawing to allow mechanism to be inserted Secure the frames without arms to th...

Page 13: ...n manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH UNI5587 Nur UNI1751 Washer UNI1750 Washer Position the mechanism above t...

Page 14: ...tools 6 2 Tools and materials Before installing the automated device please Set up a proper omnipolar cut off device with contacts more than 3 mm apart and power source isolation Set up proper tubing...

Page 15: ...the junction pit N B the number of tubes depends on the type of installation and accessories being fitted Warning to install this at least two or three people are needed Use hoisting equipment to mov...

Page 16: ...igation on CAME cancelli automatici s p a to notify users ENGLISH Use the template to precisely mark the holes for securing the columns and wings Drill the carefully marked holes using a 12 mm bit and...

Page 17: ...to the reinforcement triangle or to the distance between the upper disc and the first of the arms Assemble the rotor arms join and secure the single arms to the side with bolts and to the reinforcing...

Page 18: ...t the upper centre swivel pin of the rotor arms into the hole in the traverse piece insert the Seeger ring into the swivel pin housing and leave the rotor arms hanging from the traverse piece suspende...

Page 19: ...without obligation on CAME cancelli automatici s p a to notify users ENGLISH Secure the arms to the frames using washers and nuts Then insert the caps UNI5587 M8 Nur UNI1751 Washer UNI1750 Washer Bol...

Page 20: ...on on CAME cancelli automatici s p a to notify users ENGLISH Secure the frames without arms to the ends of the traverse piece using nuts and washers On the bottom use appropriate plugs and bolts Warni...

Page 21: ...tible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Position the mechanism above the upper swing pin and secure it using nuts and washers UNI55...

Page 22: ...along the entire height of the column through the hole all the way up the traverse piece Control panel Power cable LED stop go lights 7 Electric wiring From the traverse piece thread the two ends of...

Page 23: ...x 1 mm2 Control and safety devices 2 x 0 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2 8 Control panel Transformer 1 Transformer connection terminals 2 1 6A accessories Fuse 3 Endpoint connection terminal 4 1 6 line...

Page 24: ...work properly with the rotation direction of the turnstile 9 1 Power Cable gland Endpoint Electromagnet Electromagnet 9 2 Connecting devices to the control panel 9 Electrical connections Note the bel...

Page 25: ...le again blocks automatically With permanently closed con tacts after 10 it is continuously activated Entrance Button or Transponder N O contact Activating the turnstile to enter With a non permanent...

Page 26: ...LISH 10 1 Securing the protective grills 10 Cladding After performing all of the electrical connections position the protective grills between the wing frames and the supporting columns Note for the s...

Page 27: ...nual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH 10 2 Securing the covers Transom cover Column covers Once all electrical con...

Page 28: ...and therefore dangerous The manu facturer is not liable for any harm or damage caused by improper wrongful or unreasonable use Impact danger Danger voltage running through parts Important general saf...

Page 29: ...ium plastic iron electrical cables consist of solid urban waste They can be recycled at authorised recycling centres Other components electronic boards remote control batteries etc may contain toxic s...

Page 30: ...sines 32 68 333014 32 68 338019 CHINA CAME Shanghai CAME Shanghai Automatic Gates Co Ltd Automatic Gates Co Ltd 1st Floor Bldg 2 No 1755 South Hongmei Road Shanghai Shanghai 200237 86 021 61255005 86...

Reviews: