Connecting the magnetic loop to the SMA module
Entry and exit command
1 - NO contact, function with C10 mode or NC contact in C5 or C9
2 - NO contact input, close only function
3 - NO contact input, open only function
4 - NO contact output indicating closed boom
5 - NO contact output indicating open boom
Each output is a clean contact with maximum capacity 1A – 24 V DC.
Connecting the devices for controlling vehicle passages
Only if the control device is connected to 2-3,
can a series of commands be sent about the number of vehicles that can pass through the
barrier. The control is performed by the coil which is connected to the magnetic sensor which will command the barrier's closing after the last
scheduled vehicle has passed through.
Connect the devices as shown in the drawing and activate function F 27.
Input for SMA magnetic sensor, (NO)
normally open contact in C10 mode,
or (NC) contact normally closed to C5
or C9.
Input for button-operated control
device, (NO) contact normally open.