F1
Total stop
Stops the boom and excludes the automatic closing.
Use a control device to resume movement.
0 =Deactivated (Default)
1 = Activated
F2
Input CX
Associate a function with the CX input.
0 =Deactivated (Default)
1 = C1 = Reopening while closing (Photocells)
4 = C4 = Obstruction wait (Photocells)
5 = C5 = Immediate closing at the opening travel end
9 = C9 = Immediate closing at the travel end during opening with obstacle waiting, during closing
10 = C10 = Immediate closing during opening with obstacle waiting during closing
F3
CY input
Associate a function with the CY input.
0 =Deactivated (Default)
1 = C1 = Reopening while closing (Photocells)
4 = C4 = Obstruction wait (Photocells)
5 = C5 = Immediate closing at the opening travel end
9 = C9 = Immediate closing at the travel end during opening with obstacle waiting, during closing
10 = C10 = Immediate closing during opening with obstacle waiting during closing
F5
Safety test
It activates the check of the correct operation of the photocells after each opening and closing command.
0 =Deactivated (Default)
1 = CX
2 = CY
3 = CX+CY
⚠
When programming, the operator needs to be in stop mode.
Functions menu
To exit the menu, wait 10 seconds or press ESC.
To enter the menu, keep the ENTER button pressed
for at least one second.
Description of the commands
PROGRAMMING
The ENTER key is for:
- accessing menus;
- confirming or memorizing set values.
The < > keys are for:
- moving from one item to another;
- increasing or decreasing values.
The ESC button is for:
- exiting menus;
- cancelling changes.
Summary of Contents for I1PB0500026