Maintained action

With the function active, the operator movement (opening or closing) is interrupted when the control device 
is released.

Activation of the function excludes all other control devices.

0 =Deactivated (Default)
1 = Activated

F9

Obstruction with motor 
stopped

With the function active, the boom remains stopped if the safety devices detect an obstacle. The function 
activates with: closed rod, open rod or after a total stop.
0 =Deactivated (Default)
1 = Activated

F10

Open warning light

It warns of the state of the barrier.
0 = Warning light on (Default) - The light stays on when the boom is moving or open.
1 = Flashing warning light - The warning light fl ashes every half second when the boom is opening and stays 
on when the boom is open. The light fl ashes every second when the boom is closing and is off  when the 
boom is closed.

F11

Encoder

It manages operator slowdowns, obstacles detection and sensitivity.
0 =Deactivated (Default)
1 = Activated

F14

Sensor type

For setting the type of control device.
0 = Transponder or card reader
1 = Keypad (Default)

F15

Luminous cord

It signals the state of the barrier by using intermittent lights.
0 = Moving boom (Default)
1 = Boom in movement and closed

F18

Additional light

For choosing the type of device connected to the output.
0 = Flashing light (Default)
1 = Cycle light.
The lighting device remains on for the opening and closing time.

The light remains off  if an automatic closing time is not set.

2 = Courtesy light.
The lighting device remains on for the time set by the [Courtesy Time] function.

F19

Cls. Automatic

Sets the time that must pass before the automatic closing is activated, once the opening travel end has been 
reached.

The function does not work if any of the safety devices trigger when an obstruction is detected, or after

a total stop, or during a power outage.
0 =Deactivated (Default)
1 > … > 180 sec.

F21

Pre-fl ashing time

Sets the early activation time before each manoeuvre.
0 =Deactivated (Default)
1 > … > 10 sec.

F22

Operating time

Sets the gearmotor working time during opening and closing.
5 > … > 120 sec.

F25

Courtesy time

Sets the lighting device operation time.
60 > … > 180 sec.

F28

Opening speed

Sets the opening speed (percentage of maximum speed).
Caution!

 

The speed parameter fi elds vary depending on the type of boom:

- for booms of 2 m to 4 m with jointed boom, set the speed percentage to between 70 and 100;
- for booms of 6 m and 8 m, set the speed percentage to between 80 and 100.
70% > … > 100%

F29

Closing speed

Sets the closing speed (percentage of maximum speed).
Caution!

 

The speed parameter fi elds vary depending on the type of boom:

- for booms of 2 m to 4 m with jointed boom, set the speed percentage to between 70 and 100;
- for booms of 6 m and 8 m, set the speed percentage to between 80 and 100.
70% > … > 100%

Summary of Contents for I1PB0500026

Page 1: ...EN English Automatic barrier I1PB0500026 I1PB0500027 I1PB0500028 INSTALLATION MANUAL FOR THE FA01260 EN...

Page 2: ...4 4...

Page 3: ...IN PLAIN SIGHT THE MACHINE S ID PLATE WHEN THE INSTALLATION IS COMPLETE ALL COMMAND AND CONTROL DEVICES MUST BE INSTALLED AT LEAST 1 85 M FROM THE PERIMETER OF THE BOOM MOVEMENT AREA OR WHERE THEY CAN...

Page 4: ...17 SMA module 18 Group of terminals for power supply and devices 19 IO RS485 control panel 20 Spring anchoring bracket 21 Anchoring plate 22 Anchoring brace PRODUCT DATA AND INFORMATION Description B...

Page 5: ...6 Encoder terminals 7 Overheating protection terminals 8 Control board fuse 9 Power supply on warning LED 10 Programming warning LED 11 Memory Roll card connector 12 Programming buttons 13 Connector...

Page 6: ...h 20 m 20 30 m Input voltage for 230 V AC control board 1P N PE 3G x 1 5 mm 2 3G x 2 5 mm 2 Flashing light 2 x 0 5 mm 2 Command and control devices 2 x 0 5 mm 2 TX Photocells 2 x 0 5 mm 2 RX photocell...

Page 7: ...to the anchoring plate INSTALLING The following illustrations are mere examples Consider that the space available where to fit the barrier and accessories will vary depending on the area where it is...

Page 8: ...the most accessible side to make any adjusting easier Place the cabinet onto the anchoring plate and fasten it using nuts and washers Preparing the barrier Remove the cover screws fit the key into th...

Page 9: ...screws Fasten the boom to the attacher using the bolts supplied with the boom Change of the boom opening direction Caution The barrier is set up for installing on the left When installing on the righ...

Page 10: ...t braces onto the boom for the anti shearing protective cover MAGNETIC SENSOR FOR DETECTING BOOM DETACHMENT OPTIONAL When applying the magnetic sensor proceed as follows run the micro switch cable thr...

Page 11: ...this manual may be changed at any time and without notice Translation of the original instructions Fit the protective cover onto the support braces and fasten it using the screws Cut the groove coveri...

Page 12: ...elet tie rod below the spring The spring should be tightened to the rod which is fastened to the lever arm Choice of balancing spring Before proceeding check that the spring you have chosen is suitabl...

Page 13: ...ncing the boom Hook the eyelet rod to the anchoring rod Release the gearmotor and manually turn the spring to increase or reduce traction The boom should stabilize at 45 Secure the counter nut and rel...

Page 14: ...dy connected To install the barrier on the right follow the instructions in the CHANGING THE BOOM OPENING DIRECTION paragraph White Brown Green Ferrite Brown Blue 24 V DC gearmotor with encoder Electr...

Page 15: ...g The sum of the connected accessories input must not exceed 40 W 2 Line voltage input at 230 V AC 1P N PE 50 60 Hz Signalling devices 1 Flashing light It ashes during the operator opening and closing...

Page 16: ...device If the contact is not used it must be deactivated during the programming 3 Control device OPEN ONLY function NO contact Allows only opening The contact can be programmed for the hold to run fun...

Page 17: ...notice Translation of the original instructions See function F60 Sleep Mode See function F60 Sleep Mode Connection with Sleep Mode DIR DELTA S photocells Connection with Sleep Mode DELTA photocells Se...

Page 18: ...t indicating open boom Each output is a clean contact with maximum capacity 1A 24 V DC Connecting the devices for controlling vehicle passages Only if the control device is connected to 2 3 can a seri...

Page 19: ...hen open The boom s opening and closing maneuvers must be performed with the inspection hatch closed To correct the boom s vertical position lower the boom open the inspection hatch turn the opening m...

Page 20: ...ith the CY input 0 Deactivated Default 1 C1 Reopening while closing Photocells 4 C4 Obstruction wait Photocells 5 C5 Immediate closing at the opening travel end 9 C9 Immediate closing at the travel en...

Page 21: ...sed F18 Additional light For choosing the type of device connected to the output 0 Flashing light Default 1 Cycle light The lighting device remains on for the opening and closing time The light remain...

Page 22: ...and 60 for 6 m and 8 m booms set the percentage to between 60 and 70 40 60 F38 Closing slow down point Sets the closing slow down start point percentage of the total travel Caution The percentage var...

Page 23: ...ces AF R700 R800 must be plugged into the connectors 1 Step step 3 Open 4 Partial opening U2 Remove user Removes one of the registered users U3 Remove all Removes all registered users 0 Deactivated De...

Page 24: ...During the calibration all safety devices will be disabled except for the PARTIAL STOP one Select A3 and press ENTER to confirm Select 1 and press ENTER to confirm the travel calibration operation The...

Page 25: ...d Press ENTER to confirm a number between 1 and 25 will start flashing for a few seconds Send the code from the transmitter or other control device such as a sensor card reader or keypad selector If y...

Page 26: ...all data users and configuration with the memory roll Procedure for memorizing all of the system s user and configuration data by using the Memory Roll so they can be used with another control board e...

Page 27: ...l The warning LED stays lit 13 series 13 Check the control devices The boom does not reach the travel end 7 series 14 Replace the AF card The boom cannot be balanced 7 15 15 Check the length ratio bet...

Page 28: ...es DISPOSING OF THE PACKAGING The packaging materials cardboard plastic and so on should be disposed of as solid household waste and simply separated from other waste for recycling Always make sure yo...

Reviews: