motor test
❶
Select
A2
. Press ENTER to confirm.
❷
Select 1 to start the test. Press ENTER to confirm...
❸
... the following [---] characters will be displayed while waiting for a command
❹
Keep pressed the < key and check whether the barrier opens.
If the operator performs a closing maneuver, invert the motor's phases (M with N).
Travel calibration
⚠
During the calibration, all safety devices will be disabled except for the PARTIAL STOP one.
❶
Select
A3
and press ENTER to confirm.
❷
Select 1 and press ENTER to confirm the travel calibration operation.
❸
The operator will perform a closing maneuver until the travel end point ...
❹
... then, the barrier will perform an opening maneuver until the travel end point.
Getting started
Once the connections are all set, have skilled, qualified staff commission the barrier into service.
Before continuing, make sure that the way is clear from any obstruction.
Power up and begin configuring the system.
Important!
Start programming by first doing the following functions:
- boom length (see function A1);
- motor test (see MOTOR TEST paragraph);
- total stop (see function F1);
- calibrating travel (see paragraph called CALIBRATING TRAVEL).