FINAL OPERATIONS
Proceed with the fi nal steps, only once you have completed all connections and made the gate operational.
Fit the panel cover and fasten it using the screws
.
Replace the inspection-hatch and the cover
. Lock the hatch by using the key and fasten the cover using the screws
.
Memory roll
Memory roll
Saving and uploading all data (users and configuration) with the memory roll
Procedure for memorizing all of the system's user and configuration data by using the Memory Roll, so they can be used with another
control board, even on another system.
Caution! Fitting and extracting the Memory Roll must be done with the mains power disconnected.
❶
Fit the Memory Roll into the its corresponding connector on the control board.
❷
Select
1
from the function
F50
and press ENTER to confirm saving data in the Memory roll.
❸
Extract the Memory roll and fit it into the connector of another control board.
❹
Select
1
from the function
F51
and press ENTER to confirm the uploading of data into the Memory Roll.
After memorizing the data, it is best to remove the Memory roll.