ENGLISH

3 Technical 

data

001PSA101101 automatic cash register 

001PSAC110 server

Power supply

230 V AC 50/60 Hz

Consumption when working

400 VA

Consumption when idle

320 VA

Peak draw

730 VA

Protection rating

IP 40

Weight

200 Kg

Operating temperature

-25° / + 55°C

Depositing temperature

0° / + 70°C

Coin container 

Up to three 1000-coin each containers 

Banknote reader 

Recognises  up to six banknote denominations in all four directions. 
Container for 1000 paid-in banknotes and for 60 change banknotes. 

Barcode reader

2 D barcode 

Receipt printer 

Thermal

EFT/POS Unmanned pay-terminal

Enabled for credit and debit card circuit 

Power supply

230 V

Container

Micro tower 

Microprocessor

Dual Core 1.5 GHz AMD Turion II

RAM

PC3-10600E DDR 3.8 GB (2 x 4 GB)

HDD

8 TB (4 x 2 TB 3.5” SATA drives) 

Network control 

Embedded NC107i PCI Express Gigabit Ethernet Server Adaptor

Dimensions

267 x 260 x 210 mm

Weight

3 kg

Operating temperature

0° / + 40°C

Depositing temperature 

0° / + 70°C

Summary of Contents for PS ONE SERIES

Page 1: ...3 D U N L Q J O L Q H SERIES PS ONE INSTALLATION MANUAL PS ONE CONTROL SYSTEMS FOR PARKING FACILITIES English EN...

Page 2: ...tem scheme and technical notes 3 2 Description of units making up the PS One system 4 3 Technical data 5 4 Connections diagram 8 5 Overall dimensions and anchoring bases 9 6 Sample installation scheme...

Page 3: ...ystem For instance be careful with all spaces that require vehicle manoeuvring room At entry there must be enough room to temporarily and comfortably stop the vehicle and perform all of the required t...

Page 4: ...TFT display for visualising the status of the functions Entry unit Unit complete with integrated plastic card reader ticket printer and reader writer and reader ISO format device for both proximity an...

Page 5: ...5 C Depositing temperature 0 70 C Coin container Up to three 1000 coin each containers Banknote reader Recognises up to six banknote denominations in all four directions Container for 1000 paid in ban...

Page 6: ...g 500 VA Consumption when idle 390 VA Peak draw 620 VA Protection rating IP 40 Weight 30 Kg Operating temperature 25 55 C Depositing temperature 0 70 C Barcode reader 2 D barcode Ticket printer Therma...

Page 7: ...ration at 100 km compared to the 50 km of heads treated with typical glass passivation Elevated range of relative humidity at least 30 80 without condensa tion Vibration IEC68 2 6 compliant Print out...

Page 8: ...other operator Barrier or other operator Entry unit Automatic cash register GSM ROUTER Input Output interface Central server Intercom station Manned manual cash register Barcode ticket reader POS rea...

Page 9: ...ncelli Automatici S p A The data and information in this manual may be updated at any time by Came Cancelli Automatici S p A which is under no obligation to notify said updates ENGLISH 5 Overall dimen...

Page 10: ...8 ver 1 0 1 0 05 2012 CAME Cancelli Automatici S p A The data and information in this manual may be updated at any time by Came Cancelli Automatici S p A which is under no obligation to notify said up...

Page 11: ...Sample installation scheme The image shown below shows a sample system installation layout with side by side entry exit lanes also shown are the measurements among the system components These must be...

Page 12: ...ancelli Automatici S p A which is under no obligation to notify said updates ENGLISH Even the automatic cash register has been sized taking into account an underlying base that is at least 120 mm high...

Page 13: ...nit board description 1 Traffic light fuse 2 Traffic light connection terminal 3 Fans and heater connection terminals 4 Barrier connection terminals 5 Barrier opening command relay switch 6 Barrier cl...

Page 14: ...d description 1 VAC power supply inputs 2 Inter lighting connection terminal 3 Fans and heater connection terminals 4 Remote alarm output terminal 5 Terminal Restart relay switch 6 Network up sensor t...

Page 15: ...he junction pit N B the number of tubes depends on the type of installation and accessories used Remove any protruding nuts or washers position the cabinet onto the base and fasten it Note install the...

Page 16: ...on the end that can hoist at least 250 kg to the eyelets on the head of the central element Pull the cable taut with a mechanical arm and then hoist the central element and place it above the base Sl...

Page 17: ...der no obligation to notify said updates ENGLISH Place the upper element atop the central one and fasten it by tightening the nine issued bolts Inside the upper compartment on the left side connect th...

Page 18: ...which is under no obligation to notify said updates ENGLISH The upper right hand compartment of the cash register is set up for a back up generator in case of power outages Unplug the upper cable of...

Page 19: ...ce the backup generator on the lower shelf Plug the end of the disconnected cable to the back of the back up generator Plug an additional cable into the back of the back up generator Plug the end of t...

Page 20: ...ation and accessories used Remove any protruding nuts or washers position the cabinet onto the base and fasten it Note install the cabinet with the inspection flap facing an easily accessible directio...

Page 21: ...celli Automatici S p A which is under no obligation to notify said updates ENGLISH 11 1 Connecting coils 11 2 Connecting barriers On the left side of the post find the bi channel sensor then connect u...

Page 22: ...by Came Cancelli Automatici S p A which is under no obligation to notify said updates ENGLISH 11 3 Traffic light connections On the board find the connection to barriers terminal see entry exit unit...

Page 23: ...he data and information in this manual may be updated at any time by Came Cancelli Automatici S p A which is under no obligation to notify said updates ENGLISH 11 4 Power supply Find the power supply...

Page 24: ...ion 11 6 Switching on 11 7 Status signal LED At the lower end of the post connect the Ethernet cable to its socket Once all electrical connections are made to start the entry and exit units press the...

Page 25: ...ode scanners magnetic card readers and optical units via USB If also features an internal socket for installing a Compact Flash board on the secondary IDE channel and can be fitted with an MLC SLC SSD...

Page 26: ...to notify said updates ENGLISH Restore the cover by tightening the four screws Make the connections as shown in the figure Make the connections on the back of the roboticket reader printer as shown in...

Page 27: ...0 1 0 05 2012 CAME Cancelli Automatici S p A The data and information in this manual may be updated at any time by Came Cancelli Automatici S p A which is under no obligation to notify said updates E...

Page 28: ...dia Automation Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A...

Reviews: