RBM 84

REM

RBM84 - 

Hardware and connections

14

Pa

g

1414

 - M

an

u

al

 c

od

e: 

FA

0

0

18

9

M

0

4

FA

0

0

18

9

M

0

4

 ve

r.

 

1

 1

0

/2

0

1

5 © C

A

M

E

 s.p.a. - T

h

e d

ata a

n

d i

n

fo

rm

ati

on p

rovi

d

ed

 in

 th

is

 m

an

u

al

 a

re s

u

b

je

ct to c

h

an

g

e at a

ny ti

m

e w

ith

ou

t p

ri

or n

oti

ce by C

A

M

E

 S

.p.a.

to successive 

Rem or Turnstile

up to 60 units

(

INPUT

 

OR

 

OUTPUT

 

CAN

 

BE

 

CONNECTED

 

TO

 

TERMINAL

 

BLOCK

 1 

OR

 2)

from Rbm84 to 

the last Rem/Turnstile

maximum distance must be 

1000 m

Connecting to A segment: 

RBM84 is at the end of the cable path

Each Rem is identifi ed by Rbm84 through 

a progressive sequential numbering (1 to 
60) regardless of the position along the path 
of the connection cable; such number (also 
called address) must be set to the appro-
priate dip selector in the base Rem card.

In the event of communication problems be-
tween the Rem and the RBM84 card, position 
Dip4 to ON on the last Rem connected.

RBM84 connection <----> REM (single segments)

Cable 

NOT INCLUDED

recommended type:

unshielded 

multipair cable 

(CAT 5 - U/UTP - AWG24) 

see Annex A

Summary of Contents for RBM84-HW

Page 1: ...x 39 0422 4941 www came it info came it Came Cancelli Automatici una societ certi cata ISO 9001 per il sistema di gestione della qualit aziendale e ISO 14001 per il sistema di gestione ambiantale Came...

Page 2: ...RBM84 connection Modem Personal Computer 13 RBM84 connection REM single segments 14 RBM84 connection REM two segments 15 Connection RBM84 REM Sensor remote control 16 Connection RBM84 REM S5000 keybo...

Page 3: ...rd selectors TSP00 sensor for transponder card LT001 reader for magnetic stripe cards WAVE sensors WA01 Twister and Guardian turnstiles The number of these devices varies depending on the type of syst...

Page 4: ...risation entrance exit recording entrance stay exit monitoring entrance and exit activation and selection controlling parking time and costs locking releasing the system and or providing real time aut...

Page 5: ...relay operating mode bistable monostable with setting of monostable closing time Selection of contact type NO NC for all digital inputs Settings for 8 different time brackets of the day Enabling disab...

Page 6: ...s p a The data and information provided in this manual are subject to change at any time without prior notice by CAME S p a Recommended cable unshielded braided multi strand CAT 5 U UTP AWG 24 Types o...

Page 7: ...rol board 2 R700 and R800 board connector 3 Sensor connection terminal 4 LBD2BN1 battery charger board connection terminals 5 Battery connection terminals 6 230V A C line connection 7 Connector termin...

Page 8: ...supply safety fuse 3 Circuit safety fuse 4 Connection terminals for transponder sensors TSP00 and reader for magnetic stripe cards LT001 5 Connectors for signal decoding cards selectors sensors transm...

Page 9: ...terminal block 3 1 6A accessory fuse 4 Limit switch connection terminal block 5 1 6A line fuse 6 Board power supply terminal block 230V A C 7 Control accessories and devices connection terminal block...

Page 10: ...e by CAME S p a Function 11 Stand Alone or OnLine mode In Stand Alone OFF the turnstile works automatically while On Line ON the turnstile is connected and controlled by RBM84 Function 12 Device numbe...

Page 11: ...2 RS232 serial port for PC connection 3 Rbm84 connection terminals RS485 serial port 4 12V A C power supply 5 RS232 cable x 1 5 m complete with connectors 6 S5000 S6000 S7000 selector code memorisati...

Page 12: ...nge at any time without prior notice by CAME S p a RS232 serial port Port COM 1 5 m cable for RS232 serial ports supplied with connectors 12V AC power supply for 230V A C power supply 50 60Hz 800 mA c...

Page 13: ...connected to RBM84 PC for remote control Telephone Line N B It is possible to use standard Hayes GSM or V92 analogue modem with RS232 connection Communication is between a PC its modem the receiving...

Page 14: ...maximum distance must be 1000 m Connecting to A segment RBM84 is at the end of the cable path Each Rem is identi ed by Rbm84 through a progressive sequential numbering 1 to 60 regardless of the posit...

Page 15: ...OUTPUT CAN BE CONNECTED TO TERMINAL BLOCK 1 OR 2 Segment A Two SEGMENT connection RBM84 can be located in any position along the cable route from the rst to the last Rem Turnstile maximum distance mus...

Page 16: ...ct to change at any time without prior notice by CAME S p a On Rem simply connect a AF43S radio frequency card and connect a TOP A433N antenna on the Rem base card Connect the receiver R501N that incl...

Page 17: ...and connections 17 Page 17 17 Manual code FA00189M04 FA00189M04 ver 1 10 2015 CAME s p a The data and information provided in this manual are subject to change at any time without prior notice by CAME...

Page 18: ...code FA00189M04 FA00189M04 ver 1 10 2015 CAME s p a The data and information provided in this manual are subject to change at any time without prior notice by CAME S p a White A Blue B Blue B White A...

Page 19: ...data and information provided in this manual are subject to change at any time without prior notice by CAME S p a TSP00 Transponder card reader TST01 Transponder proximity card Red S1 Black GND Black...

Page 20: ...s p a The data and information provided in this manual are subject to change at any time without prior notice by CAME S p a Black GND Red S1 Black GND Red S1 Maximum distance 50m Maximum distance 50m...

Page 21: ...4 ver 1 10 2015 CAME s p a The data and information provided in this manual are subject to change at any time without prior notice by CAME S p a Capable of connecting alarms magnetic coils locks etc C...

Page 22: ...any time without prior notice by CAME S p a PST001 Twister Turnstile Connection RBM84 REM Turnstile connection Only with RBM84 software version 3 or later PSHPS07 Turnstile Guardian PST001 Twister Tu...

Page 23: ...tion provided in this manual are subject to change at any time without prior notice by CAME S p a 230 VAC power supply Relay contact 230 VAC power supply Relay contact Connection RBM84 REM WAVE connec...

Page 24: ...time without prior notice by CAME S p a Provide a suitable omnipolar circuir breaker with 3 mm maximum distance between contacts to disconnect the power supply 230 VAC Partial traffic lights associat...

Page 25: ...ation connect an LBD BN1 battery recharger board and relative batteries as protection against power disruption For more complex systems with one or more REMs each group should be equipped qith a UPS t...

Page 26: ...EM n 37 REM n 38 REM n 39 REM n 40 REM n 41 REM n 42 REM n 43 REM n 44 REM n 45 REM n 46 REM n 47 REM n 48 REM n 49 REM n 50 REM n 51 REM n 52 REM n 53 REM n 54 REM n 55 REM n 56 REM n 57 REM n 58 REM...

Page 27: ...purchase additional credit to exit Users with negative credit are denied access N B Dip 1 3 4 and 5 are not used leave OFF Dip 2 OFF A user with 0 credit denied access Dip switch RBM84 Function selec...

Page 28: ...reviso Treviso Italy 33079 Sesto al Reghena Sesto al Reghena Pordenone Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 English English Manual code FA00189M04 FA00189M04 ver 1 1...

Reviews: