ZL92Z:
QUICK START GUIDE
Should the gates not operate as suggested above,
call CAME helpline
0115 921 0430
for technical support.
Important!
Ensure the wiring is complete (refer to the wiring diagram) & any required physical stops are set before
commencing with programming
Tick
1. Power on the control panel
2. Press and hold the
button for 2 seconds to access programming. (
F
1
appears on the display).
3. Disable total stop –
F
1
–
O
4. Disable safety inputs –
F
2
&
F
3
–
O
5. Disable safety test –
F
5
–
O
6. Set the number of motors –
F
4
6
–
0
7. Set the motor type –
A
1
–
2
CAUTION, Ensure the gate movement area is clear of all obstructions
8. Check the motor direction
A
2
–
1
For motor 2, press and hold
The gate should open, if not reverse the motor cables for motor 2 (Connections M2, N2)
Leave the gate in the halfway position.
For motor 1, press and hold
The gate should open, if not reverse the motor cables for motor 1 (Connections M1, N1)
Leave the gate in the halfway position.
9. Setup the Encoder
A
3
–
1
10. The Gates will now perform a close and open cycle.
12. Exit the programming using the
button.
13. Check the gate operation by pulsing across connections 2 & 7, the gate will close
Please refer to the main manual for:
Changing automatic closing time, adjusting encoder settings if required
Safety inputs should now be configured and the gate force tested as required.
Please refer to the full manual to complete the commissioning.
The installation must be carried out
by skilled and qualified personnel
button - used to perform the following operations:
• Exit the menu
• Delete the changes
• Go back to the previous screen
buttons - used to perform the following operations:
• Navigate the menu
• Increase or decrease values
button - used to perform the following operations
• Access menus
• Confirm a choice
1
2
3
1
2
3