Encoder operation
Obstruction detection when
OPENING.
The door closes again.
Obstruction detection when
CLOSING.
The door inverts its travel direction and reopens.
After three consecutive inversions, when closing, the door stays open and automatic closing is excluded. After
three consecutive opening or closing detections, the door stops.
To close the door again, press a control button or use the transmitter.
ERROR MESSAGE
The error messages appear on the display.
E 2
Calibrating the complete gate-travel
E 3
Encoder broken
E 4
Services test error
E 7
Operating time error
E 9
Closing obstruction
E10
Opening obstruction
E11
Maximum number of obstructions consecutively detected