The contents of this manual may be changed, at any time, and without notice.
One or two-leaved jointed double-paneled shutter
Unfoldable type of transmission arm
VLR08
VLR09
A
- Minimum space between the inner fi xture and the
shutter
130
160
B
- Bay width (min./max.)
One leaf, without VLR01xx batteries
One leaf, with VLR05 batteries
Two leaves, without VLR02 batteries
Two leaves with VLR02+VLR05 batteries
500 / 1050
750 / 1050
820 / 2100
970 / 2100
500 / 1050
750 / 1050
900 / 2100
970 / 2100
F
- Width of internal panel (min./max.)
140 / 170
170 / 240
The angle
must always exceed 90°; install a simple strike plate
for this.
For this application, fi t a corner protection
for the arm.
Cable types and minimum thicknesses
Connection
Cable type
Cable length
1 < 10 m
10 < 20 m
20 < 30 m
Power supply to control panel 230 V
FROR CEI 20-22
CEI EN 50267-2-1
3G x 1.5 mm
2
3G x 2.5 mm
2
3G x 4 mm
2
Accessories powered at 24 V
2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 1 mm
2
Command and safety device
2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
Home & building automation connections
CAT5 - U/UTP - AWG24
max 1200 m
☞
If the cable lengths differ from that specified in the table, then you must determine the cable diameter based on the actual
power draw from the connected devices and according to the CEI EN 60204-1 standard.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the actual
power draw and distances. For connecting products that are not contemplated in this manual, see the literature accompanying
said products
GENERAL INSTRUCTIONS FOR INSTALLING
⚠
Installation must be carried out by expert qualified personnel and in full compliance with the regulations in force.
Preliminary checks
•
Check that the operator fixing point is protected from possible knocks, and that the fixing surface is solid. Also check that
appropriate screws, plugs, etc. are used to fix the panel;
•
Set up suitable conduits and tubes to safely run the electrical cables through and to protect them from mechanical damage.
•
Remove the shutter opening stops and replace them with strike plates.
•
Make sure the angles between the two leaves always exceeds 90°.
Tools and materials
Make sure you have all the tools and materials you will need for installing in total
safety and in compliance with applicable regulations. The figure shows some of the
equipment installers will need.