Set a slowdown of a few seconds after each opening and closing command.
[SET TRAVEL]
[Soft Start]
[Deactivated] (Default)
[Activated]
Amperometric sensitivity
This function only appears if the [Encoder] function is deactivated.
With the function deactivated, the leaves stop if an obstacle is detected.
Manage the sensitivity of obstacle detection.
Depending on the parameter set in the [Confi g] function, there are diff erent possible operations in the event of an obstacle.
[Time limit switch] - it stops the gate leaves during a manoeuvre.
[Limit-switch] - invert travel during a manoeuvre.
[Slow.] - invert travel during a manoeuvre and stop the leaves during slowdown.
[Op.LS-Cl.Slow.] - invert travel during a manoeuvre and stop the leaves during closing slowdown.
[SET TRAVEL]
[Amperom. sens.]
[Deactivated] (Default)
[Activated]
Travel amperometrics
Adjust the amperometric sensitivity.
The function appears only if the [Amperom. sens.] function is activated.
[SET TRAVEL]
[Amperom. travel]
Slowdown time
Set the slowdown time before each limit switch.
This function appears only with the [Op.LS-Cl.Slow.] or [Slow.] parameters from the [Confi g] function.
[SET TRAVEL]
[Slow. time] function
from [0 s] to [30 s] (Default 20 s)
Sensitivity
Activate the obstacle-detection sensitivity.
[ENCODER]
This function appears only
if the [ENCODER] parameter is
activated from the [Confi g] function
[Sensitivity]
[Activated] (Default)
[Deactivated]
Travel sensitivity
Adjust the obstruction detection sensitivity during boom travel.
This function appears only if the [Sensitivity] function is active.
[ENCODER]
This function appears only
if the [ENCODER] parameter is
activated from the [Confi g] function
[Travel sens.]
Summary of Contents for ZLJ24
Page 33: ...Control panel for 24 V gearmotors ZLJ24 ZLJ24Z INSTALLATION MANUAL FA01571 EN EN English...
Page 97: ...24 ZLJ24 ZLJ24Z FA01571 RU RU...
Page 98: ...2 FA01571 RU 04 2021 CAME S p A 2006 42 CE 2006 42 CE 2006 42 CE CAME www came com III...
Page 99: ...3 FA01571 RU 04 2021 CAME S p A 1 5 2006 42 CE...
Page 100: ...4 FA01571 RU 04 2021 CAME S p A CAME S p A UNI EN ISO 14001...
Page 104: ...8 FA01571 RU 04 2021 CAME S p A 1 2 3 4 20...
Page 105: ...9 FA01571 RU 04 2021 CAME S p A 1 2 6 3 295 215...
Page 127: ...31 FA01571 RU 04 2021 CAME S p A 1 2 C1 C3 C4 C7...