Key-switch selector and/or closing button
(N.O. contact).
- For commanding the gate to stop.
Key-switch selector and/or pedestrian or partial opening
(N.O. contact).
The command goesto only one gate leaf (gearmotor M2).
- - See
[FUNCTIONS] menu
→
[Command 2-3P]
.
Key-switch selector and/or control buttons
(N.O. contact).
- For commanding the opening and closing of the gate.
- See
[FUNCTIONS] menu
→
[Command 2-7]
.
Key-switch selector and/or opening button
(N.O. contact).
- For commanding the gate to open.
Stop button
(N.C. contact).
- For commanding the gate to stop while excluding the automatic-closing time
cycle. To resume movement, press a button on the control or the transmitter
button.
&
If unused, deactivate the contact in the [FUNCTIONS] menu
→
[Total Stop].
Command and control devices
Before fitting any snap-in cards (such as the AF or R700), YOU MUST CUT OFF THE POWER MAINS, and disconnect
the power mains.
&
Fit the R700 decoder card
so the transponder sensor or the
card reader can be detected.
- R800 so thekeypad selector
can be detected.
Transponder or card
reader
Keypad
selector