Menu 1st level
Menu 2nd level
Options
Default
[CY input]
[Disabled] / [C1] / [C2] / [C3] / [C4] / [C7] / [C8]
[C3]
See [CX Input]
[CZ input]
[Disabled] / [C1] / [C2] / [C3] / [C4] / [C7] / [C8]
[Disabled]
See [CX Input]
[Cl. Thrust]
[Disabled] / [Enabled]
[Disabled]
When the leaf-swing reaches the limit-switch, the operator performs a closing
thrust for a some seconds.
[Lock]
[Disabled] / [Closing] / [Opening] / [Open-Close]
[Disabled]
Releasesthe electric lock during the closing and opening stops.
[Config]
[Timed LS] / [Limit-switch] / [SloDwn] / [OpLs-Clslodwn] /
[ENCODER]
[ENCODER]
Configuring the opening and closing slow-downs.
• [Slo. Dwn.]
* Opening and closing slow-downs.
• [OpLs-Clos.Slo.]
* Opening limit-switch and closing slow-down.
• [ENCODER]
Manage slow-downs , detect obstructions and sensitivity.
• [Timed LS]
Timed limit-switch.
• [Limit switch]
Opening and closing limit-switches.
*
Slowdowns configurable with the
[Slo.dwn. time] function
in the
[SET TI-
MES]
[Limit switch]
[N.C. / N.O.]
[N.C.]
Configuring the limit-switches as normally opened or closed contacts.
&
This function only appears if one of the following options is selected
[Limit-
switch]
,
[OpLs-Clos.Slo.]
or
[Slo. Dwn.]
from the
[Config] function
.
[Command 2-7]
function
[Open-Close] / [Op. Stop Cl.]
[Open-Close]
Configurating contact 2-7 in step-step (open-close) or sequential (open-stop-
close-stop).
[Command 2-3P]
function
[Partial] / [Pedestrians]
[Pedestrian]
Configuring contact 2-3P to pedestrian opening (total opening of the second gate-
leaf) or partial (partial opening of the second gate leaf) depending on the time set
on
[Partial Op.] function
in the
[SET TIMES] menu
.
[Light E] function [Courtesy] / [Cycle]
[Cycle]
Configuring the light connected to E-E3:
Outdoor light in following mode:
-
Courtesy
It stays on for a preset five minutes;
-
Cycle
, it stays lit from the moment that the gate leaf starts opening until it is com-
pletely closed (including the automatic closing time). In case the automatic closing
in not inserted, it stays on only during the movement.
[Output B1-B2]
[Monostable] / [Bistable]
[Bistable]
Configuring contact B1-B2 in Monostable or Bistable mode (switch).
[Slo. dwn. Speed] [-
◦◦◦
+]
[-
・・・
+]
Setting the opening and closing or only the closing speed if the slow-down is
configured as [
OpLs-Clslodwn
].
For AXO motors with cod. 001AX302304 and 001AX402306 set the slow-down
speed to the maximum value. The setting is in any case subject to an on-site
system-compliance inspection, pursuant to European Directive 2006/42/CE.
[Motor Number]
[M1+M2] / [M2];
[M1+M2]