12
DMX
IT
ALIANO
POLSKI
ESP
AÑOL
FRANCAIS
DEUTSCH
ENGLISH
B
B
A
A
INSTALLATION
Thanks to its integrated rubber feet, the lamp can be positioned in a suitable location on a level surface. on a traverse is carried out with two
Omega brackets, mounted on the base of the device (A). 2 x Omega brackets are included. Suitable beam clamps are available as an option.
Ensure firm connections and secure the spotlight to the securing lug (B) with a suitable safety cable. The distance between the spotlight and
illuminated areas and objects must be at least 5 metres. The distance to other devices and combustible materials must be at least 0.2 metres.
Important note:
Overhead mounting requires extensive experience, including the calculation of the load limit values of the
installation material and regular safety inspection of all installation materials and spotlights.
If you do not have these qualifications, do not attempt to perform an installation yourself. Refer instead to a qualified professional.
REPLACING THE LAMP
Important:
Replacement of the lamp may be carried out by qualified personnel only. If you do not have these qualifications, do not attempt
to replace a lamp.yourself. Refer instead to a qualified professional.
A hot discharge lamp is under high pressure and can therefore spontaneously explode. Let the lamp cool for at least 30
minutes before opening it.
Use as a spare bulb only the model specified in the data sheet.
Do not touch the glass bulb of the lamp with bare fingers, the lamp must be spotlessly clean.
When replacing the lamp, wear protective glasses and protective gloves.
1. Fully disconnect the spotlight from the mains (pull out the plug)!
2. Remove the two screws securing the lamp cover and remove the top cover from the spotlight head.
3. Loosen the four screws of the lamp holder only about one turn.
4. Push the lamp in the direction of the arrow down against the spring bracket and tilt backwards out of the top bracket.